Influence of the coordination between transmission and distribution networks on the allocation of harmonic emission limits

This paper investigates the efficacy of the joint and separate methods of allocating harmonic emission limits defined in the IEC and the VDE AR-N German technical reports. Both methods are applied in a test network with 380 kV, 220 kV and 110 kV voltage levels. Based on the allocated emission limits a harmonic load flow is performed to calculate the resulting harmonic voltage levels at all nodes. A Monte Carlo Simulation is applied in order to consider the probabilistic aspect of concurrency and phase angle diversity. Moreover, various network scenarios are tested, which include different types of generation (modular multilevel converter / synchronous generator) and different aggregated medium voltage network equivalents. The harmonic voltages calculated at each node are then compared with the planning levels, in order to analyse the efficiency of the method s with respect to the different voltage levels. It can be shown, that due to resonance condition the separate coordination of voltage levels leads to an exceedance of planning levels at certain nodes.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.1798
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of the coordination between transmission and distribution networks on the allocation of harmonic emission limits

Jan Meyer, Ana María Blanco, Erik Ole Matthes
IET conference proceedings.
Power Line Communications and Noise
article

Influence of the coordination between transmission and distribution networks on the allocation of harmonic emission limits

Jan Meyer, Ana María Blanco, Erik Ole Matthes
article en

Abstract

This paper investigates the efficacy of the joint and separate methods of allocating harmonic emission limits defined in the IEC and the VDE AR-N German technical reports. Both methods are applied in a test network with 380 kV, 220 kV and 110 kV voltage levels. Based on the allocated emission limits a harmonic load flow is performed to calculate the resulting harmonic voltage levels at all nodes. A Monte Carlo Simulation is applied in order to consider the probabilistic aspect of concurrency and phase angle diversity. Moreover, various network scenarios are tested, which include different types of generation (modular multilevel converter / synchronous generator) and different aggregated medium voltage network equivalents. The harmonic voltages calculated at each node are then compared with the planning levels, in order to analyse the efficiency of the method s with respect to the different voltage levels. It can be shown, that due to resonance condition the separate coordination of voltage levels leads to an exceedance of planning levels at certain nodes.

IET conference proceedings.Vol. 2025(14)
Technische Universität Dresden (DE)
Openalex Percentile: Top 71%
Power Line Communications and Noise
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of the coordination between transmission and distribution networks on the allocation of harmonic emission limits — Jan Meyer, Ana María Blanco, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS