Increased reliability of smart distribution transformers for efficient operation of LV distribution electric grids

Smart distribution transformers with on-load tap changers (OLTC) and real-time sensors have been implemented to address voltage fluctuations caused by prosumers and electric vehicles in low-voltage (LV) networks. Since this technology is new, it is crucial to ensure its reliability throughout its lifespan. To achieve this, new Stress Approval Tests have been introduced, including 500,000 operations under nominal voltage conditions. Additionally, 200,000 operations have been performed at nominal current. After these operations, additional tests were conducted to ensure the integrity of the transformer. These tests were carried out in manufacturing laboratories and in the Smart Grid Laboratory, UDEX.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.1626
Primary Topic
Belt Conveyor Systems Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Increased reliability of smart distribution transformers for efficient operation of LV distribution electric grids

Alvaro Ortiz, Álvaro Camuñas, Ibon Larracoechea, Pablo Cirujano
IET conference proceedings.
Belt Conveyor Systems Engineering
article

Increased reliability of smart distribution transformers for efficient operation of LV distribution electric grids

Alvaro Ortiz, Álvaro Camuñas, Ibon Larracoechea, Pablo Cirujano
article en

Abstract

Smart distribution transformers with on-load tap changers (OLTC) and real-time sensors have been implemented to address voltage fluctuations caused by prosumers and electric vehicles in low-voltage (LV) networks. Since this technology is new, it is crucial to ensure its reliability throughout its lifespan. To achieve this, new Stress Approval Tests have been introduced, including 500,000 operations under nominal voltage conditions. Additionally, 200,000 operations have been performed at nominal current. After these operations, additional tests were conducted to ensure the integrity of the transformer. These tests were carried out in manufacturing laboratories and in the Smart Grid Laboratory, UDEX.

IET conference proceedings.Vol. 2025(14)
Ormazabal (Germany) (DE)
Openalex Percentile: Top 70%
Belt Conveyor Systems Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.