Impact of new uses on the thermal behaviour of a 30-40-year-old distribution transformer

Enedis operates 870,000 distribution transformers, some of which are more than 40 years old and will be facing new challenges: (i) the impact of climate change, which is likely to lead to a rise in temperature in MV/LV substations; (ii) new uses (electric vehicles, integration of renewable energies, etc.), which will globally increase the load on transformers. The article focuses on a realistic but rather pessimistic case study: a 400 kVA class C0Ck transformer, in a substation at the foot of a building, in an urban residential environment, supplying 265 households and located in Toulon (a city on the Mediterranean coast).The thermal calculations assess the ability of the 30-to 40-year-old transformers currently in service to meet the challenges of the next quarter century, which combine the effects of climate change and the integration of new residential uses.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.1618
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of new uses on the thermal behaviour of a 30-40-year-old distribution transformer

Djamel Hadbi, N. Barnel, François-Xavier Rommelard
IET conference proceedings.
Power Transformer Diagnostics and Insulation
article

Impact of new uses on the thermal behaviour of a 30-40-year-old distribution transformer

Djamel Hadbi, N. Barnel, François-Xavier Rommelard
article en

Abstract

Enedis operates 870,000 distribution transformers, some of which are more than 40 years old and will be facing new challenges: (i) the impact of climate change, which is likely to lead to a rise in temperature in MV/LV substations; (ii) new uses (electric vehicles, integration of renewable energies, etc.), which will globally increase the load on transformers. The article focuses on a realistic but rather pessimistic case study: a 400 kVA class C0Ck transformer, in a substation at the foot of a building, in an urban residential environment, supplying 265 households and located in Toulon (a city on the Mediterranean coast).The thermal calculations assess the ability of the 30-to 40-year-old transformers currently in service to meet the challenges of the next quarter century, which combine the effects of climate change and the integration of new residential uses.

IET conference proceedings.Vol. 2025(14)
Eau de Paris (France) (FR), Territoires, Villes, Environnement & Société (FR)
Openalex Percentile: Top 71%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of new uses on the thermal behaviour of a 30-40-year-old distribution transformer — Djamel Hadbi, N. Barnel, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS