Medium voltage joint design options for higher conductor temperature (110 °C)

A new special polypropylene insulation (PP-insulation) for medium voltage cables (MV-cables) permits a permanent conductor temperature of 110 °C for cables in continuous operation. However, connectors and accessories are only tested an approved for a conductor temperature of 90 °C. To ensure a long lifetime of the connectors and the insulating part of the joints, the connection areas should be designed as a kind of a heat sink. Using MV-cables with different conductor cross-sections (95 mm2, 300 mm2) and materials (aluminium (Al) or copper (Cu)), it is shown how such a heat sink can be designed. The intention is to limit the temperature in the connection area of the joint to 90°C, while the temperature of the conductor of the PP-insulated medium-voltage cable, which is not thermally affected by the joint, can reach 110°C. The ampacity of these MV-cables with PP-insulation is compared with cables made of cross-linked polyethylene (XLPE) insulation. The investigations were conducted using calculations with a thermal model based on the Thermal Network Method (TNM) on a single cable joint arrangement. Different ambient temperatures of air and soil conditions were taken into account.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.1789
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Medium voltage joint design options for higher conductor temperature (110 °C)

Robert Adam, Gert Stauch, K.-D. Haim, Kai-Uwe Bentowski
IET conference proceedings.
Thermal Analysis in Power Transmission
article

Medium voltage joint design options for higher conductor temperature (110 °C)

Robert Adam, Gert Stauch, K.-D. Haim, Kai-Uwe Bentowski
article en

Abstract

A new special polypropylene insulation (PP-insulation) for medium voltage cables (MV-cables) permits a permanent conductor temperature of 110 °C for cables in continuous operation. However, connectors and accessories are only tested an approved for a conductor temperature of 90 °C. To ensure a long lifetime of the connectors and the insulating part of the joints, the connection areas should be designed as a kind of a heat sink. Using MV-cables with different conductor cross-sections (95 mm2, 300 mm2) and materials (aluminium (Al) or copper (Cu)), it is shown how such a heat sink can be designed. The intention is to limit the temperature in the connection area of the joint to 90°C, while the temperature of the conductor of the PP-insulated medium-voltage cable, which is not thermally affected by the joint, can reach 110°C. The ampacity of these MV-cables with PP-insulation is compared with cables made of cross-linked polyethylene (XLPE) insulation. The investigations were conducted using calculations with a thermal model based on the Thermal Network Method (TNM) on a single cable joint arrangement. Different ambient temperatures of air and soil conditions were taken into account.

IET conference proceedings.Vol. 2025(14)
Cicor (Germany) (DE), Zittau/Görlitz University of Applied Sciences (DE), Technische Universität Dresden (DE)
Openalex Percentile: Top 63%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Medium voltage joint design options for higher conductor temperature (110 °C) — Robert Adam, Gert Stauch, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS