Assessing the flicker emission of electric arc furnaces in CO2-neutral steel production: a case study

The steel industry's transition to CO2-neutral production methods is driving the usage of direct reduction processes using hydrogen or natural gas. Electric arc furnaces (EAFs) playing a critical role in processing directly reduced iron. EAFs are known for their dynamic power consumption, which leads to a significant flicker emission. Conventional methods for estimating the flicker of an EAF during the planning stage tend to overestimate the emission due to simplifications and lack of input parameters, which can result in exceeding permissible emission limits even with advanced compensation systems. This paper presents in a case study the calculation of the flicker emission of a planned EAF. Flicker emissions of an existing, similar behaving EAF were measured in various operational modes. Using a current-based flickermeter the flicker emission of the planned EAF at the new connection point is calculated and assessed for the emission limit values. As a result, the connection was verified to meet the grid operator's requirements with realistic flicker compensation.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.1910
Primary Topic
Engineering and Environmental Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the flicker emission of electric arc furnaces in CO2-neutral steel production: a case study

Robert Stiegler, Jan Christian Meyer, Stefan Geigenmüller
IET conference proceedings.
Engineering and Environmental Studies
article

Assessing the flicker emission of electric arc furnaces in CO2-neutral steel production: a case study

Robert Stiegler, Jan Christian Meyer, Stefan Geigenmüller
article en

Abstract

The steel industry's transition to CO2-neutral production methods is driving the usage of direct reduction processes using hydrogen or natural gas. Electric arc furnaces (EAFs) playing a critical role in processing directly reduced iron. EAFs are known for their dynamic power consumption, which leads to a significant flicker emission. Conventional methods for estimating the flicker of an EAF during the planning stage tend to overestimate the emission due to simplifications and lack of input parameters, which can result in exceeding permissible emission limits even with advanced compensation systems. This paper presents in a case study the calculation of the flicker emission of a planned EAF. Flicker emissions of an existing, similar behaving EAF were measured in various operational modes. Using a current-based flickermeter the flicker emission of the planned EAF at the new connection point is calculated and assessed for the emission limit values. As a result, the connection was verified to meet the grid operator's requirements with realistic flicker compensation.

IET conference proceedings.Vol. 2025(14)
ArcelorMittal (Germany) (DE), Technische Universität Dresden (DE)
Openalex Percentile: Top 64%
Engineering and Environmental Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.