Impact of electromagnetic coupling on common 110 KV/400 KV overhead lines on a 110 KV grid

It is sometimes unavoidable to run high and extra-high voltage circuits on common overhead line towers. The spatial proximity between the conductors inevitably leads to inductive and capacitive coupling between both voltage levels. However, it is not necessary to entirely eliminate coupling, provided it doesn’t have a detrimental effect on the operation of the overhead line or on the other components of the grids involved (including compliance with the relevant limit values for voltage and current asymmetries). This paper describes the basic principles and the modelling of the electromagnetic coupling of a 400 kV and a parallel 110 kV (low-impedance neutral point grounding) system. Based on their geometry, critical configurations are shown and the dimensions for induced voltages and influenced currents are given. Measures to avoid ferroresonance are presented.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.1631
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of electromagnetic coupling on common 110 KV/400 KV overhead lines on a 110 KV grid

F. Wirtz, Mathias Schulze, Matthias Schilcher, Uwe Schmidt
IET conference proceedings.
High-Voltage Power Transmission Systems
article

Impact of electromagnetic coupling on common 110 KV/400 KV overhead lines on a 110 KV grid

F. Wirtz, Mathias Schulze, Matthias Schilcher, Uwe Schmidt
article en

Abstract

It is sometimes unavoidable to run high and extra-high voltage circuits on common overhead line towers. The spatial proximity between the conductors inevitably leads to inductive and capacitive coupling between both voltage levels. However, it is not necessary to entirely eliminate coupling, provided it doesn’t have a detrimental effect on the operation of the overhead line or on the other components of the grids involved (including compliance with the relevant limit values for voltage and current asymmetries). This paper describes the basic principles and the modelling of the electromagnetic coupling of a 400 kV and a parallel 110 kV (low-impedance neutral point grounding) system. Based on their geometry, critical configurations are shown and the dimensions for induced voltages and influenced currents are given. Measures to avoid ferroresonance are presented.

IET conference proceedings.Vol. 2025(14)
Zittau/Görlitz University of Applied Sciences (DE), BH Consulting (Ireland) (IE), Bayer (Germany) (DE)
Openalex Percentile: Top 71%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.