Case study for reducing voltage sag impacts in industrial clients

This paper presents a methodological approach to reducing the impact of voltage sags on industrial customer processes. This methodology has been systematized using software developed by the Brazilian electricity distribution company Neoenergia Coelba and has provided quick and efficient results. The development in question follows a systematic methodology that consists of identifying the customer's sensitivity to define their vulnerability area. This is followed by actions on the distribution network, as well as actions on the customer's internal installations that will reduce their vulnerability area and consequently the impact of voltage sag on their facilities. This method uses information from the Geographic Information System (GIS) network register, the power distribution company's grid protection systems, and data from power quality analyzers, including the GODEL PQA 900, a class A power quality analyzer with continuous waveform register function developed by Neoenergia Coelba through the research, development, and innovation program, regulated by the Brazilian National Electric Energy Agency (ANEEL).

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.2242
Primary Topic
Elevator Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case study for reducing voltage sag impacts in industrial clients

Gustavo Travassos A. da Silva, Moira B. Prates
IET conference proceedings.
Elevator Systems and Control
article

Case study for reducing voltage sag impacts in industrial clients

Gustavo Travassos A. da Silva, Moira B. Prates
article en

Abstract

This paper presents a methodological approach to reducing the impact of voltage sags on industrial customer processes. This methodology has been systematized using software developed by the Brazilian electricity distribution company Neoenergia Coelba and has provided quick and efficient results. The development in question follows a systematic methodology that consists of identifying the customer's sensitivity to define their vulnerability area. This is followed by actions on the distribution network, as well as actions on the customer's internal installations that will reduce their vulnerability area and consequently the impact of voltage sag on their facilities. This method uses information from the Geographic Information System (GIS) network register, the power distribution company's grid protection systems, and data from power quality analyzers, including the GODEL PQA 900, a class A power quality analyzer with continuous waveform register function developed by Neoenergia Coelba through the research, development, and innovation program, regulated by the Brazilian National Electric Energy Agency (ANEEL).

IET conference proceedings.Vol. 2025(14)
Hospital São Rafael (BR)
Openalex Percentile: Top 63%
Elevator Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.