Two-dimensional approach for condition assessment of high voltage air-insulated circuit breakers

Modern asset management in power systems increasingly emphasizes condition-based maintenance strategies to ensure the safe, efficient, and sustainable operation of critical equipment. This contribution presents a two-dimensional systematic evaluation approach for the condition assessment of high voltage air-insulated circuit breakers, integrating diagnostic data into two indices: the lifetime consumption index for long-term renewal planning and the failure risk index for short-term maintenance prioritization. The methodology employs a tiered assessment model, ranging from visual inspections to comprehensive analyses requiring equipment de-energization, with results aggregated and weighted to provide actionable insights. A field trial conducted with Netze Duisburg GmbH on twelve 110 kV circuit breakers validated the practical application of the system, highlighting its effectiveness in identifying maintenance priorities and extending asset lifecycles.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.1825
Primary Topic
Power System Reliability and Maintenance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-dimensional approach for condition assessment of high voltage air-insulated circuit breakers

Thomas Brock, Max Bondorf, Philipp Bolz, Markus Zdrallek et al.
IET conference proceedings.
Power System Reliability and Maintenance
article

Two-dimensional approach for condition assessment of high voltage air-insulated circuit breakers

Thomas Brock, Max Bondorf, Philipp Bolz, Markus Zdrallek, Alexei Babizki, Korbinian Maurer, Niklas Bäcker
article en

Abstract

Modern asset management in power systems increasingly emphasizes condition-based maintenance strategies to ensure the safe, efficient, and sustainable operation of critical equipment. This contribution presents a two-dimensional systematic evaluation approach for the condition assessment of high voltage air-insulated circuit breakers, integrating diagnostic data into two indices: the lifetime consumption index for long-term renewal planning and the failure risk index for short-term maintenance prioritization. The methodology employs a tiered assessment model, ranging from visual inspections to comprehensive analyses requiring equipment de-energization, with results aggregated and weighted to provide actionable insights. A field trial conducted with Netze Duisburg GmbH on twelve 110 kV circuit breakers validated the practical application of the system, highlighting its effectiveness in identifying maintenance priorities and extending asset lifecycles.

IET conference proceedings.Vol. 2025(14)
University of Wuppertal (DE), Stadtwerke Duisburg (Germany) (DE), Maschinenfabrik Reinhausen (Germany) (DE), BG Klinikum Duisburg (DE)
Openalex Percentile: Top 64%
Power System Reliability and Maintenance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.