Protection of MV networks including zig-zag grounding transformers

Zig-zag grounding transformers are often used in Medium Voltage (MV) networks to provide a return path for ground fault current. The protection of these MV networks is challenging. On the one hand, transformer differential unit does not have enough sensibility to detect internal ground faults on the delta side of a YD transformer with the zig-zag transformer in the protection zone, due to the zig-zag current limitation, the power transformer ratio and the presence of capacitive current on the MV feeders. Restricted Earth Fault (REF) unit can be used to increase the sensibility, however special care must be taken for external phase-phase-ground faults with CT saturation. The common directional comparison unit that compares the angle between the ground and neutral currents cannot be used. Instead, the use of the external fault detector that supervises the transformer differential unit is proposed. On the other hand, the neutral directional unit based on the angle between neutral voltage and current wrongly activates the forward fault condition on the healthy feeders. A directional unit based on the magnitude of the zero-sequence impedance instead of on its angle is proposed. Several RTDS simulations are done to study the existence of the mentioned problems with the conventional protection units and to confirm their solution using the new units.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.2408
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Protection of MV networks including zig-zag grounding transformers

Roberto Cimadevilla, Carmen M. Domínguez, José Ángel G. Viosca
IET conference proceedings.
Power Systems Fault Detection
article

Protection of MV networks including zig-zag grounding transformers

Roberto Cimadevilla, Carmen M. Domínguez, José Ángel G. Viosca
article en

Abstract

Zig-zag grounding transformers are often used in Medium Voltage (MV) networks to provide a return path for ground fault current. The protection of these MV networks is challenging. On the one hand, transformer differential unit does not have enough sensibility to detect internal ground faults on the delta side of a YD transformer with the zig-zag transformer in the protection zone, due to the zig-zag current limitation, the power transformer ratio and the presence of capacitive current on the MV feeders. Restricted Earth Fault (REF) unit can be used to increase the sensibility, however special care must be taken for external phase-phase-ground faults with CT saturation. The common directional comparison unit that compares the angle between the ground and neutral currents cannot be used. Instead, the use of the external fault detector that supervises the transformer differential unit is proposed. On the other hand, the neutral directional unit based on the angle between neutral voltage and current wrongly activates the forward fault condition on the healthy feeders. A directional unit based on the magnitude of the zero-sequence impedance instead of on its angle is proposed. Several RTDS simulations are done to study the existence of the mentioned problems with the conventional protection units and to confirm their solution using the new units.

IET conference proceedings.Vol. 2025(14)
GAIKER Technology Centre (ES), Torrens University Australia (AU), Servicio Murciano de Salud (ES)
Openalex Percentile: Top 63%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Protection of MV networks including zig-zag grounding transformers — Roberto Cimadevilla, Carmen M. Domínguez, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS