Microfluidic Isolation of Aptamers for Intracellular Measurement of Radio-Responsive Proteins

In large-scale radiological events, there is a need to triage affected individuals based on their biological absorbed dose. Biodosimetry measures biological responses in relation to the received dose. Radiation-responsive protein biomarkers in peripheral blood lymphocytes, especially intracellular proteins, have been validated for biodosimetry with immunochemical-based measurement methods. However, these antibody-based assays can suffer from stability and batch-to-batch variations. Aptamers are single-stranded oligonucleotide alternatives to antibodies that are stable and much smaller in size, making them ideal probes for intracellular targets. However, few aptamers have been developed against intracellular targets, and these efforts are especially hampered due to the time-consuming nature of the conventional aptamer selection method. An efficient method for isolating aptamers against intracellular radiation-responsive proteins is not available yet. Herein, we used a microfluidic aptamer isolation method to develop an aptamer against the intracellular radiation biomarker BAX in blood lymphocytes. The isolated aptamer has a dissociation constant of 6.95 nM against human BAX protein and a bright detail similarity score of 1.9 when colocalizing with anti-BAX aptamer intracellularly. The in situ labeling of the intracellular BAX protein also shows the aptamer can be used to differentiate 2.5 Gy or 3 Gy of radiation in ex vivo human and in vivo mouse peripheral blood samples exposed to X-rays. In conclusion, this proof-of-concept study indicates that the microfluidic-enabled aptamer isolation method could be used for the development of a panel of targeted intracellular proteins for radiation biodosimetry applications.

Authors

Institutions

Publication Details

Journal
Radiation
Published
2025-10-14
DOI
https://doi.org/10.3390/radiation5040030
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic Isolation of Aptamers for Intracellular Measurement of Radio-Responsive Proteins

Kechun Wen, Leah Nemzow, Sally A. Amundson, Yaru Han et al.
Radiation
Advanced Biosensing Techniques and Applications
article

Microfluidic Isolation of Aptamers for Intracellular Measurement of Radio-Responsive Proteins

Kechun Wen, Leah Nemzow, Sally A. Amundson, Yaru Han, Xin Meng, Helen Turner, Qiao Lin
article en

Abstract

In large-scale radiological events, there is a need to triage affected individuals based on their biological absorbed dose. Biodosimetry measures biological responses in relation to the received dose. Radiation-responsive protein biomarkers in peripheral blood lymphocytes, especially intracellular proteins, have been validated for biodosimetry with immunochemical-based measurement methods. However, these antibody-based assays can suffer from stability and batch-to-batch variations. Aptamers are single-stranded oligonucleotide alternatives to antibodies that are stable and much smaller in size, making them ideal probes for intracellular targets. However, few aptamers have been developed against intracellular targets, and these efforts are especially hampered due to the time-consuming nature of the conventional aptamer selection method. An efficient method for isolating aptamers against intracellular radiation-responsive proteins is not available yet. Herein, we used a microfluidic aptamer isolation method to develop an aptamer against the intracellular radiation biomarker BAX in blood lymphocytes. The isolated aptamer has a dissociation constant of 6.95 nM against human BAX protein and a bright detail similarity score of 1.9 when colocalizing with anti-BAX aptamer intracellularly. The in situ labeling of the intracellular BAX protein also shows the aptamer can be used to differentiate 2.5 Gy or 3 Gy of radiation in ex vivo human and in vivo mouse peripheral blood samples exposed to X-rays. In conclusion, this proof-of-concept study indicates that the microfluidic-enabled aptamer isolation method could be used for the development of a panel of targeted intracellular proteins for radiation biodosimetry applications.

RadiationVol. 5(4)
Columbia University Irving Medical Center (US), Columbia University (US)
National Institutes of Health, Irving Medical Center, Columbia University, National Cancer Institute, National Institute of General Medical Sciences, National Institute of Allergy and Infectious Diseases
Openalex Percentile: Top 74%
Advanced Biosensing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.