Analysis of Prestress Loss and Structural Performance of Box-Type Prestressed Concrete Girders on the Cakung Flyover

The increasing traffic congestion in East Jakarta, particularly at the Cakung intersection, prompted the construction of the Cakung Flyover, designed with a prestressed concrete box-girder system. However, field observations revealed several serviceability issues, including hairline cracks (0.10–0.28 mm), vertical deflections of 18–25 mm, and a 30.5 % reduction in effective prestress compared with theoretical design values. This research aimed to analyze prestress losses and their structural implications through an integrated analytical–empirical approach combining field measurements, theoretical modeling, and validation using SAP2000 and MATLAB simulations. The results showed that the box-girder section (A = 5.65 m², Wa = 5.43 m³, Wb = 2.76 m³) exhibited satisfactory flexural rigidity but experienced frictional losses at tendon angular deviations, particularly near anchorage zones. The tropical environment—average temperature 33 °C and relative humidity 85–90 %—accelerated creep, shrinkage, and relaxation in the 7-wire low-relaxation strands. Consequently, measured prestress losses were 1.3–1.6 times higher than those predicted by standard codes. This study confirms that tropical humidity significantly amplifies prestress degradation and highlights the need for climate-specific calibration of SNI 2847:2019 coefficients. The research contributes a calibrated correlation between tendon eccentricity (eₛ ≈ 1.195 m), deflection, and stress relaxation, enabling more accurate prediction and control of structural performance. The proposed framework provides practical guidelines for tendon configuration, prestress monitoring, and maintenance strategies for prestressed concrete flyovers in humid tropical regions such as Jakarta.

Authors

Institutions

Publication Details

Journal
Jurnal Riset Ilmu Teknik
Published
2025-09-30
DOI
https://doi.org/10.59976/jurit.v3i2.187
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Prestress Loss and Structural Performance of Box-Type Prestressed Concrete Girders on the Cakung Flyover

Aldo Dion Selvistre, Viona Yeni, Putut Keswardi
Jurnal Riset Ilmu Teknik
Structural Behavior of Reinforced Concrete
article

Analysis of Prestress Loss and Structural Performance of Box-Type Prestressed Concrete Girders on the Cakung Flyover

Aldo Dion Selvistre, Viona Yeni, Putut Keswardi
article en

Abstract

The increasing traffic congestion in East Jakarta, particularly at the Cakung intersection, prompted the construction of the Cakung Flyover, designed with a prestressed concrete box-girder system. However, field observations revealed several serviceability issues, including hairline cracks (0.10–0.28 mm), vertical deflections of 18–25 mm, and a 30.5 % reduction in effective prestress compared with theoretical design values. This research aimed to analyze prestress losses and their structural implications through an integrated analytical–empirical approach combining field measurements, theoretical modeling, and validation using SAP2000 and MATLAB simulations. The results showed that the box-girder section (A = 5.65 m², Wa = 5.43 m³, Wb = 2.76 m³) exhibited satisfactory flexural rigidity but experienced frictional losses at tendon angular deviations, particularly near anchorage zones. The tropical environment—average temperature 33 °C and relative humidity 85–90 %—accelerated creep, shrinkage, and relaxation in the 7-wire low-relaxation strands. Consequently, measured prestress losses were 1.3–1.6 times higher than those predicted by standard codes. This study confirms that tropical humidity significantly amplifies prestress degradation and highlights the need for climate-specific calibration of SNI 2847:2019 coefficients. The research contributes a calibrated correlation between tendon eccentricity (eₛ ≈ 1.195 m), deflection, and stress relaxation, enabling more accurate prediction and control of structural performance. The proposed framework provides practical guidelines for tendon configuration, prestress monitoring, and maintenance strategies for prestressed concrete flyovers in humid tropical regions such as Jakarta.

Jurnal Riset Ilmu TeknikVol. 3(2)
Nasional University (ID)
Openalex Percentile: Top 69%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.