Whole-cell biosensors with regulatory circuits based on a synthetic dual-input promoter enabling the highly sensitive detection of ultra-trace Cd2+

The research on whole-cell biosensors tailored for trace and ultra-trace detection remains limited and the biosensors based on natural bacterial heavy metal resistance mechanisms have common issues of low sensitivity. In this study, we designed a promoter P <sub><i>T7-cadO</i></sub> using the Cadmium ions (Cd<sup>2+</sup>)-binding protein binding site <i>cadO</i> with the T7 promoter at first and constructed a single-input whole-cell biosensor, which was named CP100, whose detection limit for Cd<sup>2+</sup> met the WHO requirement, yet its response and sensitivity were quite low. We further introduced the <i>lacI</i> and <i>lac operator</i> (<i>lacO</i>) as the signal amplifier to construct a dual-input promoter P <sub><i>T7-cadO-lacO-cadO</i></sub> and developed a biosensor named LC100, whose response and sensitivity were significantly improved, but background leakage became a new problem. Then we redesigned the gene circuit based on the regulatory circuit LCPM-2, which has the structure of "CadR-P <sub><i>J23100</i></sub> -P <sub><i>T7-cadO-lacO-cadO</i></sub> -mRFP1-LacI", with the LacI protein as the autoregulatory negative feedback model and finally obtained the biosensor named LC100-2, which achieved the detection of ultra-trace Cd<sup>2+</sup> (0.00001-0.02 nM), with the sensitivity of 3748.22 times that of CP100. Moreover, LC100-2 demonstrated excellent specificity to Cd<sup>2+</sup> among four other divalent metal ions and good anti-interference capability in the mixed divalent metal ions system. The results of the real water sample tests demonstrated that precise quantitative detection of Cd<sup>2+</sup> with a final concentration of 0.001-0.02 nM could be achieved by adding only a small volume of the sample (1 μL). This finding showed promising application potential in the field of trace detection. Additionally, the regulatory circuit LCPM-2 based on the unique dual-input promoter enhanced responses and reduced background leakage simultaneously, thereby providing an innovative strategy for the design and simplification of biosensors' circuits.

Authors

Institutions

Publication Details

Journal
Synthetic and Systems Biotechnology
Published
2025-09-12
DOI
https://doi.org/10.1016/j.synbio.2025.09.008
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Whole-cell biosensors with regulatory circuits based on a synthetic dual-input promoter enabling the highly sensitive detection of ultra-trace Cd2+

Xiaoqiang Jia, Shuting Hu, Yibin Yang, Yuke Qin
1 citations
Synthetic and Systems Biotechnology
Advanced biosensing and bioanalysis techniques
0.81
article

Whole-cell biosensors with regulatory circuits based on a synthetic dual-input promoter enabling the highly sensitive detection of ultra-trace Cd2+

Xiaoqiang Jia, Shuting Hu, Yibin Yang, Yuke Qin
article en
1 citations

Abstract

The research on whole-cell biosensors tailored for trace and ultra-trace detection remains limited and the biosensors based on natural bacterial heavy metal resistance mechanisms have common issues of low sensitivity. In this study, we designed a promoter P <sub><i>T7-cadO</i></sub> using the Cadmium ions (Cd<sup>2+</sup>)-binding protein binding site <i>cadO</i> with the T7 promoter at first and constructed a single-input whole-cell biosensor, which was named CP100, whose detection limit for Cd<sup>2+</sup> met the WHO requirement, yet its response and sensitivity were quite low. We further introduced the <i>lacI</i> and <i>lac operator</i> (<i>lacO</i>) as the signal amplifier to construct a dual-input promoter P <sub><i>T7-cadO-lacO-cadO</i></sub> and developed a biosensor named LC100, whose response and sensitivity were significantly improved, but background leakage became a new problem. Then we redesigned the gene circuit based on the regulatory circuit LCPM-2, which has the structure of "CadR-P <sub><i>J23100</i></sub> -P <sub><i>T7-cadO-lacO-cadO</i></sub> -mRFP1-LacI", with the LacI protein as the autoregulatory negative feedback model and finally obtained the biosensor named LC100-2, which achieved the detection of ultra-trace Cd<sup>2+</sup> (0.00001-0.02 nM), with the sensitivity of 3748.22 times that of CP100. Moreover, LC100-2 demonstrated excellent specificity to Cd<sup>2+</sup> among four other divalent metal ions and good anti-interference capability in the mixed divalent metal ions system. The results of the real water sample tests demonstrated that precise quantitative detection of Cd<sup>2+</sup> with a final concentration of 0.001-0.02 nM could be achieved by adding only a small volume of the sample (1 μL). This finding showed promising application potential in the field of trace detection. Additionally, the regulatory circuit LCPM-2 based on the unique dual-input promoter enhanced responses and reduced background leakage simultaneously, thereby providing an innovative strategy for the design and simplification of biosensors' circuits.

Synthetic and Systems BiotechnologyVol. 11
Tianjin University (CN)
Openalex Percentile: Top 23%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.