Whole-cell biosensors with regulatory circuits based on a synthetic dual-input promoter enabling the highly sensitive detection of ultra-trace Cd2+
The research on whole-cell biosensors tailored for trace and ultra-trace detection remains limited and the biosensors based on natural bacterial heavy metal resistance mechanisms have common issues of low sensitivity. In this study, we designed a promoter P <sub><i>T7-cadO</i></sub> using the Cadmium ions (Cd<sup>2+</sup>)-binding protein binding site <i>cadO</i> with the T7 promoter at first and constructed a single-input whole-cell biosensor, which was named CP100, whose detection limit for Cd<sup>2+</sup> met the WHO requirement, yet its response and sensitivity were quite low. We further introduced the <i>lacI</i> and <i>lac operator</i> (<i>lacO</i>) as the signal amplifier to construct a dual-input promoter P <sub><i>T7-cadO-lacO-cadO</i></sub> and developed a biosensor named LC100, whose response and sensitivity were significantly improved, but background leakage became a new problem. Then we redesigned the gene circuit based on the regulatory circuit LCPM-2, which has the structure of "CadR-P <sub><i>J23100</i></sub> -P <sub><i>T7-cadO-lacO-cadO</i></sub> -mRFP1-LacI", with the LacI protein as the autoregulatory negative feedback model and finally obtained the biosensor named LC100-2, which achieved the detection of ultra-trace Cd<sup>2+</sup> (0.00001-0.02 nM), with the sensitivity of 3748.22 times that of CP100. Moreover, LC100-2 demonstrated excellent specificity to Cd<sup>2+</sup> among four other divalent metal ions and good anti-interference capability in the mixed divalent metal ions system. The results of the real water sample tests demonstrated that precise quantitative detection of Cd<sup>2+</sup> with a final concentration of 0.001-0.02 nM could be achieved by adding only a small volume of the sample (1 μL). This finding showed promising application potential in the field of trace detection. Additionally, the regulatory circuit LCPM-2 based on the unique dual-input promoter enhanced responses and reduced background leakage simultaneously, thereby providing an innovative strategy for the design and simplification of biosensors' circuits.
Authors
- Xiaoqiang Jia (ORCID: https://orcid.org/0000-0002-1756-1926)
- Shuting Hu (ORCID: https://orcid.org/0000-0003-1813-4309)
- Yibin Yang (ORCID: https://orcid.org/0009-0007-2094-2555)
- Yuke Qin
Institutions
- Tianjin University (CN)
Publication Details
- Journal
- Synthetic and Systems Biotechnology
- Published
- 2025-09-12
- DOI
- https://doi.org/10.1016/j.synbio.2025.09.008
- Citations
- 1
- Primary Topic
- Advanced biosensing and bioanalysis techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.81