Earth-fault protection challenges for modern distribution power systems

Modern distribution power systems are characterized by extensive use of power cables and often have unusual grounding impedance arrangements. Typical examples are offshore MV windfarm collector systems. In the paper, the basic physics behind the earth-faults in high impedance grounded networks will be explained first. When and how earth-fault protection relays based on steady-state 3Io and 3Uo quantities can be used will be clarified. Then, a more universal transient based earth-fault protection method will be explained. Its determination of the earth-fault direction is based on the short-term built-up transient at the beginning of the fault. This transient is, to a large extent, independent of the neutral point treatment; thus, the same principles can be applied without any modification in all types of high-impedance grounded or isolated power systems. Restriking or intermittent earth-faults will also be successfully detected and cleared by such earth-fault protection.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.1844
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Earth-fault protection challenges for modern distribution power systems

Samir Aganović, Z. Gajić, Reijo Pajunen, Marcin Krakowski et al.
IET conference proceedings.
Power Systems Fault Detection
article

Earth-fault protection challenges for modern distribution power systems

Samir Aganović, Z. Gajić, Reijo Pajunen, Marcin Krakowski, Hamdy Faramawy, Simon Peulić
article en

Abstract

Modern distribution power systems are characterized by extensive use of power cables and often have unusual grounding impedance arrangements. Typical examples are offshore MV windfarm collector systems. In the paper, the basic physics behind the earth-faults in high impedance grounded networks will be explained first. When and how earth-fault protection relays based on steady-state 3Io and 3Uo quantities can be used will be clarified. Then, a more universal transient based earth-fault protection method will be explained. Its determination of the earth-fault direction is based on the short-term built-up transient at the beginning of the fault. This transient is, to a large extent, independent of the neutral point treatment; thus, the same principles can be applied without any modification in all types of high-impedance grounded or isolated power systems. Restriking or intermittent earth-faults will also be successfully detected and cleared by such earth-fault protection.

IET conference proceedings.Vol. 2025(14)
Hitachi (Sweden) (SE)
Openalex Percentile: Top 63%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.