Challenges and solutions of harmonic monitoring application as per IEEE 519 and IEC 61000-4-30 standards

Modern power grids are evolving with renewables, and these comprises of complex power electronic converters which injects huge amount of harmonics into the system. The harmonics injected by any source in the grid should be within the limits as specified in IEEE 519 standard to maintain power quality. Harmonic monitoring application helps to monitor the harmonic content in the form of Total Harmonic Distortion (THD), Individual Harmonic Distortion (IHD) and Total Demand Distortion (TDD) at Point of Common Coupling (PCC). When THD/IHD/TDD values exceed the specified limits, harmonic monitoring application provides alarm so that user can disconnect the harmonic source to maintain power quality in the system. Dedicated power quality device is needed to monitor the harmonic parameters in the grid, due to high computational requirements. With the optimizations in the calculation of harmonic parameters discussed in this paper, harmonic monitoring application can be offered in protection and control IED (Intelligent Electronic Device).

Authors

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.2050
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Challenges and solutions of harmonic monitoring application as per IEEE 519 and IEC 61000-4-30 standards

Bathala Teja, A. V. S. S. R. Sai, A Gurujith
IET conference proceedings.
Sensor Technology and Measurement Systems
article

Challenges and solutions of harmonic monitoring application as per IEEE 519 and IEC 61000-4-30 standards

Bathala Teja, A. V. S. S. R. Sai, A Gurujith
article en

Abstract

Modern power grids are evolving with renewables, and these comprises of complex power electronic converters which injects huge amount of harmonics into the system. The harmonics injected by any source in the grid should be within the limits as specified in IEEE 519 standard to maintain power quality. Harmonic monitoring application helps to monitor the harmonic content in the form of Total Harmonic Distortion (THD), Individual Harmonic Distortion (IHD) and Total Demand Distortion (TDD) at Point of Common Coupling (PCC). When THD/IHD/TDD values exceed the specified limits, harmonic monitoring application provides alarm so that user can disconnect the harmonic source to maintain power quality in the system. Dedicated power quality device is needed to monitor the harmonic parameters in the grid, due to high computational requirements. With the optimizations in the calculation of harmonic parameters discussed in this paper, harmonic monitoring application can be offered in protection and control IED (Intelligent Electronic Device).

IET conference proceedings.Vol. 2025(14)
Openalex Percentile: Top 66%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Challenges and solutions of harmonic monitoring application as per IEEE 519 and IEC 61000-4-30 standards — Bathala Teja, A. V. S. S. R. Sai, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS