Challenges of new technologies non-based in SF6 for operating and protecting MV power transformers of distribution networks

The introduction of new SF6-free technologies in MV electrical networks requires to adequately solving the challenges, which were well solved with SF6 technologies along last decades and still today. One of those challenges is to provide appropriate protection and operation to MV power transformers. This paper shows which are the necessary considerations to take when selecting the technologies, and how a new simple design of three-position switch-disconnector and earthing switch operating inIndustrial Natural Airis able to provide equivalent performances as SF6 based ones provide for most of MV power transformers used in for distribution networks at voltages of up to 24 kV.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.2070
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Challenges of new technologies non-based in SF6 for operating and protecting MV power transformers of distribution networks

Sergio Sebastián, Joseba Arostegui, J. M. Inchausti
IET conference proceedings.
High voltage insulation and dielectric phenomena
article

Challenges of new technologies non-based in SF6 for operating and protecting MV power transformers of distribution networks

Sergio Sebastián, Joseba Arostegui, J. M. Inchausti
article en

Abstract

The introduction of new SF6-free technologies in MV electrical networks requires to adequately solving the challenges, which were well solved with SF6 technologies along last decades and still today. One of those challenges is to provide appropriate protection and operation to MV power transformers. This paper shows which are the necessary considerations to take when selecting the technologies, and how a new simple design of three-position switch-disconnector and earthing switch operating inIndustrial Natural Airis able to provide equivalent performances as SF6 based ones provide for most of MV power transformers used in for distribution networks at voltages of up to 24 kV.

IET conference proceedings.Vol. 2025(14)
Ormazabal (Germany) (DE)
Openalex Percentile: Top 77%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.