Point-on-wave voltage sag impact on AC contactor sensitivity: a comparative study

Voltage sag is primarily defined by its root-mean-square (rms) magnitude and duration, but the Point-on-Wave (PoW) at which it occurs also plays a crucial role. The sensitivity of AC contactors to voltage sags can significantly impact industrial operations, particularly in petrochemical plants where trip events lead to substantial financial losses. A collaborative study between a major petrochemical company and TNB Energy Services (TNBES) explored the effects of PoW voltage sags on operational AC contactors. Following findings presented at CIRED 2019, further tests were conducted in 2018 and 2021, focusing on different firing angles from 0° to 90° in 15° increments. The results revealed that AC contactors from the older substation exhibited greater variations in immunity levels, suggesting that prolonged operation and aging components contribute to increased sensitivity to voltage sags. Comparing sample results from 2018 and 2021, this study further highlights that PoW variations evolve over time, influencing long-term equipment reliability. Findings reinforce the importance of PoW considerations in voltage sag immunity assessments, particularly for aging industrial equipment.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.2061
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Point-on-wave voltage sag impact on AC contactor sensitivity: a comparative study

Khalis Mokhtar, Hazri Dahalan Md. Razip
IET conference proceedings.
Magnetic Field Sensors Techniques
article

Point-on-wave voltage sag impact on AC contactor sensitivity: a comparative study

Khalis Mokhtar, Hazri Dahalan Md. Razip
article en

Abstract

Voltage sag is primarily defined by its root-mean-square (rms) magnitude and duration, but the Point-on-Wave (PoW) at which it occurs also plays a crucial role. The sensitivity of AC contactors to voltage sags can significantly impact industrial operations, particularly in petrochemical plants where trip events lead to substantial financial losses. A collaborative study between a major petrochemical company and TNB Energy Services (TNBES) explored the effects of PoW voltage sags on operational AC contactors. Following findings presented at CIRED 2019, further tests were conducted in 2018 and 2021, focusing on different firing angles from 0° to 90° in 15° increments. The results revealed that AC contactors from the older substation exhibited greater variations in immunity levels, suggesting that prolonged operation and aging components contribute to increased sensitivity to voltage sags. Comparing sample results from 2018 and 2021, this study further highlights that PoW variations evolve over time, influencing long-term equipment reliability. Findings reinforce the importance of PoW considerations in voltage sag immunity assessments, particularly for aging industrial equipment.

IET conference proceedings.Vol. 2025(14)
Universiti Malaysia Pahang Al-Sultan Abdullah (MY), Tenaga Nasional Berhad (Malaysia) (MY)
Openalex Percentile: Top 71%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Point-on-wave voltage sag impact on AC contactor sensitivity: a comparative study — Khalis Mokhtar, Hazri Dahalan Md. Razip · IET conference proceedings. (2025) | TGRS Research Map | TGRS