Assessing the temporal and spatial impact of renewable energy integration on medium voltage transformer failures

The increasing integration of renewable energy sources (RES) in distribution networks causes a change in the operation of the grid, particularly in loading patterns, which potentially affects the failure rate of medium voltage distribution transformers. Two complementary methods are assessed to review the impact of RES on transformer failure rates. Both methods are applied on the service area of the Dutch distribution system operator Stedin. The temporal analysis reveals significant hourly correlations between failure rates and renewable generation profiles, although no seasonal trends are observed. The spatial analysis highlights localised effects, with moderate correlations in specific areas, particularly where photovoltaic generation is oriented east-west. Despite the lack of a trend indicating increased failure rates due to increasing RES penetration, the findings suggest localised stress on assets and show the need for further research into long-term ageing effects.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-14
DOI
https://doi.org/10.1049/icp.2025.2272
Primary Topic
Power System Reliability and Maintenance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the temporal and spatial impact of renewable energy integration on medium voltage transformer failures

Peter van der Wielen, Anne van der Molen, Phuong H. Nguyen, Yifan Zhang et al.
IET conference proceedings.
Power System Reliability and Maintenance
article

Assessing the temporal and spatial impact of renewable energy integration on medium voltage transformer failures

Peter van der Wielen, Anne van der Molen, Phuong H. Nguyen, Yifan Zhang, Niek Brekelmans
article en

Abstract

The increasing integration of renewable energy sources (RES) in distribution networks causes a change in the operation of the grid, particularly in loading patterns, which potentially affects the failure rate of medium voltage distribution transformers. Two complementary methods are assessed to review the impact of RES on transformer failure rates. Both methods are applied on the service area of the Dutch distribution system operator Stedin. The temporal analysis reveals significant hourly correlations between failure rates and renewable generation profiles, although no seasonal trends are observed. The spatial analysis highlights localised effects, with moderate correlations in specific areas, particularly where photovoltaic generation is oriented east-west. Despite the lack of a trend indicating increased failure rates due to increasing RES penetration, the findings suggest localised stress on assets and show the need for further research into long-term ageing effects.

IET conference proceedings.Vol. 2025(14)
Tennet (Netherlands) (NL), Steinhauser (Czechia) (CZ), Eindhoven University of Technology (NL)
Openalex Percentile: Top 65%
Power System Reliability and Maintenance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.