HYDRODYNAMIC LOADS ON THE WALLS OF A TURBINE BLOCK WITH A COUNTER VORTEX DAMPER

The article discusses the use of a counter vortex water flow energy dissipater when using a medium-pressure hydroelectric power station's conduit as a spillway. A design of a counter vortex damper in the chamber of a hydraulic turbine impeller with damping of excess flow energy in the cone of the draft tube is proposed. Research was carried out on pressure pulsations on the walls of a hydraulic model of a turbine block, as a result of which spectra and standards of pressure pulsations on the walls of a draft tube cone were obtained during operation of the model with and without a damper. It has been shown that passing water through a turbine unit of a medium-pressure HPP with the working impeller removed is unacceptable and leads to the destruction of the structure. It was found that the installation of a counter vortex damper in the impeller chamber reduces the dynamic loads on the walls of the draft tube cone by 6–7 times compared to the mode without a damper. It is concluded that the flow of water through a turbine unit of a medium-pressure HPP with a counter vortex damper installed in the impeller chamber satisfies the safety standards of hydraulic structures. The need to supply atmospheric air to the counter vortex damper via a special air duct has been established.

Authors

Publication Details

Journal
International Journal for Computational Civil and Structural Engineering
Published
2025-09-29
DOI
https://doi.org/10.22337/2587-9618-2025-21-3-158-171
Primary Topic
Fluid Dynamics and Turbulent Flows
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HYDRODYNAMIC LOADS ON THE WALLS OF A TURBINE BLOCK WITH A COUNTER VORTEX DAMPER

A. L. Zuykov, Genrih Orehov, Mikhail K. Sklyadnev
International Journal for Computational Civil and Structural Engineering
Fluid Dynamics and Turbulent Flows
article

HYDRODYNAMIC LOADS ON THE WALLS OF A TURBINE BLOCK WITH A COUNTER VORTEX DAMPER

A. L. Zuykov, Genrih Orehov, Mikhail K. Sklyadnev
article en

Abstract

The article discusses the use of a counter vortex water flow energy dissipater when using a medium-pressure hydroelectric power station's conduit as a spillway. A design of a counter vortex damper in the chamber of a hydraulic turbine impeller with damping of excess flow energy in the cone of the draft tube is proposed. Research was carried out on pressure pulsations on the walls of a hydraulic model of a turbine block, as a result of which spectra and standards of pressure pulsations on the walls of a draft tube cone were obtained during operation of the model with and without a damper. It has been shown that passing water through a turbine unit of a medium-pressure HPP with the working impeller removed is unacceptable and leads to the destruction of the structure. It was found that the installation of a counter vortex damper in the impeller chamber reduces the dynamic loads on the walls of the draft tube cone by 6–7 times compared to the mode without a damper. It is concluded that the flow of water through a turbine unit of a medium-pressure HPP with a counter vortex damper installed in the impeller chamber satisfies the safety standards of hydraulic structures. The need to supply atmospheric air to the counter vortex damper via a special air duct has been established.

International Journal for Computational Civil and Structural EngineeringVol. 21(3)
Openalex Percentile: Top 69%
Fluid Dynamics and Turbulent Flows
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.