Increase Officers' Knowledge about Equipment Calibration Through Baby Incubator Maintenance Activities

Baby Incubator is a medical device designed to support and protect newborns, particularly those requiring special care. In certain conditions, newborns may not be physiologically stable, and one common issue is hypothermia—defined as a body temperature below the normal range. To address this, baby incubators must maintain a temperature that corresponds to the infant’s condition. However, many existing incubator devices still suffer from inaccuracies in temperature readings, which can compromise their effectiveness, especially in terms of usability and monitoring by medical personnel. The objective of this study is to design a baby incubator with adjustable temperature settings and integrated safety limit controls, aimed at enhancing the knowledge and responsiveness of healthcare workers in monitoring neonatal conditions. The research utilizes Arduino Uno as the control system and a Liquid Crystal Display (LCD) character module for visualizing temperature data. The results of the study show that the temperature error values at 34°C, 35°C, 36°C, and 37°C were less than 1%, indicating high accuracy. It is recommended that temperature monitoring be complemented by ambient temperature measurements to improve the overall effectiveness of the incubator system.

Institutions

Publication Details

Journal
Community Empowerment in Health
Published
2025-10-13
DOI
https://doi.org/10.36568/ceh20203
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Increase Officers' Knowledge about Equipment Calibration Through Baby Incubator Maintenance Activities

Community Empowerment in Health
Quality and Safety in Healthcare
article

Increase Officers' Knowledge about Equipment Calibration Through Baby Incubator Maintenance Activities

article en

Abstract

Baby Incubator is a medical device designed to support and protect newborns, particularly those requiring special care. In certain conditions, newborns may not be physiologically stable, and one common issue is hypothermia—defined as a body temperature below the normal range. To address this, baby incubators must maintain a temperature that corresponds to the infant’s condition. However, many existing incubator devices still suffer from inaccuracies in temperature readings, which can compromise their effectiveness, especially in terms of usability and monitoring by medical personnel. The objective of this study is to design a baby incubator with adjustable temperature settings and integrated safety limit controls, aimed at enhancing the knowledge and responsiveness of healthcare workers in monitoring neonatal conditions. The research utilizes Arduino Uno as the control system and a Liquid Crystal Display (LCD) character module for visualizing temperature data. The results of the study show that the temperature error values at 34°C, 35°C, 36°C, and 37°C were less than 1%, indicating high accuracy. It is recommended that temperature monitoring be complemented by ambient temperature measurements to improve the overall effectiveness of the incubator system.

Community Empowerment in HealthVol. 2(2)
Poltekkes Kemenkes Surabaya
Openalex Percentile: Top 47%
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.