Quantitative Evaluation of Vacuum-Induced Morphological Changes in Knee-Disarticulation: A Case Study for Personalized Prosthetic Socket Design

Achieving a best-fit prosthetic socket is essential to comfort, functional performance, and long-term residual limb health in lower-limb amputees. To our knowledge, no previous study has quantitatively compared in vivo residual limb geometry under vacuum versus non-vacuum conditions using high-resolution computed tomography (CT). In this patient-specific case study of a bilateral knee-disarticulation (KD) amputee, both residual limbs were scanned under standardized conditions: one enclosed in a vacuum-compressed sleeve and the contralateral limb untreated as a natural control, thereby minimizing inter-subject variability. CT-based 3D reconstructions enabled volumetric and cross-sectional quantification, including symmetry/asymmetry analysis of paired limbs, while finite element analysis (FEA) assessed the biomechanical consequences for socket performance. Vacuum application resulted in a 4.1% reduction in total limb volume and a 5.3% reduction in mid-thigh cross-sectional area, with regionally asymmetric displacement of soft tissues. FEA demonstrated that vacuum-induced geometry reduced peak Von Mises stresses (27.43 MPa to 15.83 MPa), minimized maximum displacement (1.72 mm to 0.88 mm), and improved minimum factor of safety (~2.0 to ~3.0), while homogenizing contact pressure distribution (peak fell from 2.42 to 1.28 N/mm2). These findings provide preliminary CT-based evidence that vacuum application induces measurable morphological adaptations with implications for socket conformity, comfort, and load transfer. While limited to a single patient, this study highlights the potential of vacuum-induced modeling to inform personalized prosthetic socket design.

Authors

Institutions

Publication Details

Journal
Symmetry
Published
2025-10-13
DOI
https://doi.org/10.3390/sym17101719
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Evaluation of Vacuum-Induced Morphological Changes in Knee-Disarticulation: A Case Study for Personalized Prosthetic Socket Design

Ebrahim Ismaiel, Mhd Ayham Darwich, Hasan Mhd Nazha, Maysaa Shash et al.
Symmetry
Prosthetics and Rehabilitation Robotics
article

Quantitative Evaluation of Vacuum-Induced Morphological Changes in Knee-Disarticulation: A Case Study for Personalized Prosthetic Socket Design

Ebrahim Ismaiel, Mhd Ayham Darwich, Hasan Mhd Nazha, Maysaa Shash, Kaysse Ebrahim, Lourance Kamleh
article en

Abstract

Achieving a best-fit prosthetic socket is essential to comfort, functional performance, and long-term residual limb health in lower-limb amputees. To our knowledge, no previous study has quantitatively compared in vivo residual limb geometry under vacuum versus non-vacuum conditions using high-resolution computed tomography (CT). In this patient-specific case study of a bilateral knee-disarticulation (KD) amputee, both residual limbs were scanned under standardized conditions: one enclosed in a vacuum-compressed sleeve and the contralateral limb untreated as a natural control, thereby minimizing inter-subject variability. CT-based 3D reconstructions enabled volumetric and cross-sectional quantification, including symmetry/asymmetry analysis of paired limbs, while finite element analysis (FEA) assessed the biomechanical consequences for socket performance. Vacuum application resulted in a 4.1% reduction in total limb volume and a 5.3% reduction in mid-thigh cross-sectional area, with regionally asymmetric displacement of soft tissues. FEA demonstrated that vacuum-induced geometry reduced peak Von Mises stresses (27.43 MPa to 15.83 MPa), minimized maximum displacement (1.72 mm to 0.88 mm), and improved minimum factor of safety (~2.0 to ~3.0), while homogenizing contact pressure distribution (peak fell from 2.42 to 1.28 N/mm2). These findings provide preliminary CT-based evidence that vacuum application induces measurable morphological adaptations with implications for socket conformity, comfort, and load transfer. While limited to a single patient, this study highlights the potential of vacuum-induced modeling to inform personalized prosthetic socket design.

SymmetryVol. 17(10)
University of Parma (IT), Al Andalus University (SY), Syrian Private University (SY), Otto-von-Guericke-Universität Magdeburg (DE)
Openalex Percentile: Top 72%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.