Upgrading the ICIM-CI Model to Account for Amplitude-Modulated Interference Signals

This article presents a methodology for extracting the integrated circuit immunity model–conducted immunity (ICIM-CI) model of an electronic circuit, specifically to account for amplitude-modulated (AM) interference signals. The device under test (DUT) is a voltage follower circuit based on an operational amplifier. When its input is subjected to AM interference, the output voltage varies in accordance with the interference envelope. It is shown that the amplitude of the DUT’s output voltage depends on the modulation frequency of the interfering signal. To capture this dependence, the direct power injection test bench has been modified to inject hypoband and mesoband interference signals. This setup allows the extraction of a transfer function describing the dependence of the DUT’s output amplitude on the modulation frequency. This transfer function is then used to enhance the ICIM-CI model of the DUT, enabling accurate simulation of its behavior under exposure to AM interference signals.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Electromagnetic Compatibility
Published
2025-10-13
DOI
https://doi.org/10.1109/temc.2025.3615767
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Upgrading the ICIM-CI Model to Account for Amplitude-Modulated Interference Signals

D. A. Hardy, Tristan Dubois, Franck Salvador, Geneviève Duchamp et al.
IEEE Transactions on Electromagnetic Compatibility
Sensor Technology and Measurement Systems
article

Upgrading the ICIM-CI Model to Account for Amplitude-Modulated Interference Signals

D. A. Hardy, Tristan Dubois, Franck Salvador, Geneviève Duchamp, Antoine Duguet
article en

Abstract

This article presents a methodology for extracting the integrated circuit immunity model–conducted immunity (ICIM-CI) model of an electronic circuit, specifically to account for amplitude-modulated (AM) interference signals. The device under test (DUT) is a voltage follower circuit based on an operational amplifier. When its input is subjected to AM interference, the output voltage varies in accordance with the interference envelope. It is shown that the amplitude of the DUT’s output voltage depends on the modulation frequency of the interfering signal. To capture this dependence, the direct power injection test bench has been modified to inject hypoband and mesoband interference signals. This setup allows the extraction of a transfer function describing the dependence of the DUT’s output amplitude on the modulation frequency. This transfer function is then used to enhance the ICIM-CI model of the DUT, enabling accurate simulation of its behavior under exposure to AM interference signals.

IEEE Transactions on Electromagnetic CompatibilityVol. 68(1)
Thales (Portugal) (PT), Centre National de la Recherche Scientifique (FR), Université de Bordeaux (FR), Thales (Australia) (AU), Thales (France) (FR), Laboratoire de l'Intégration du Matériau au Système (FR), Institut Polytechnique de Bordeaux (FR)
Openalex Percentile: Top 66%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Upgrading the ICIM-CI Model to Account for Amplitude-Modulated Interference Signals — D. A. Hardy, Tristan Dubois, et al. · IEEE Transactions on Electromagnetic Compatibility (2025) | TGRS Research Map | TGRS