Life-Vest Embedded Ballistocardiogram Measurement System for Underwater Heart Rate and Heart Rate Variability Monitoring

Seamless monitoring of vital signs in stranded persons could enhance rescue operations by providing physiological status and prioritizing efforts accordingly. In this work, we explore the feasibility of a skin-contact-free system embedded within life vest for heart rate (HR) and heart rate variability (HRV) monitoring based on ballistocardiogram (BCG). The system is validated using human subject experiments performed both on land and underwater, and at different temperatures, against an electrocardiogram (ECG)-based gold-standard reference. Three different state-of-art processing pipelines were adapted to extract heartbeat timings. Multiple standard metrics were used to assess their performance - the adapted method based on Brüser et al. outperformed two other explored methods. HR correlation coefficients achieved by the best method were 0.92 (baseline on land), 0.90 (cold pressor on land), 0.87 (cold pool), and 0.96 (hot tub) [p < 0.001]. Bland-Altman analysis showed tight limits of agreement (LoA =1.96 SD) across all environments, ranging from 2.37 bpm (hot tub) to 4.95 bpm (cold pressor on land). The detection rate reached ≥67.82% (pool), with a modified efficiency of ≥79.35% (pool). Different HRV metrics in time and frequency domains were calculated. Mean inter-beat intervals (mean IBIs) and standard deviation of successive normal-to-normal intervals (SDNN) outperformed other metrics, in terms of mean absolute error (≤ 12.77 ms and ≤ 16.28 ms, respectively) and LoA (≤ 36.48 ms). This work presents significant progress in underwater cardiac physiology monitoring without ECG, demonstrating the feasibility of a BCG-based monitoring system integrated into a life vest to aid in rescue operations.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-10-13
DOI
https://doi.org/10.1109/jsen.2025.3618770
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Life-Vest Embedded Ballistocardiogram Measurement System for Underwater Heart Rate and Heart Rate Variability Monitoring

Onur Selim Kılıç, Neil Harris, Afra Nawar, Jin‐Oh Hahn et al.
IEEE Sensors Journal
Non-Invasive Vital Sign Monitoring
article

Life-Vest Embedded Ballistocardiogram Measurement System for Underwater Heart Rate and Heart Rate Variability Monitoring

Onur Selim Kılıç, Neil Harris, Afra Nawar, Jin‐Oh Hahn, Gabriela I. Cestero, Jacob M. Cook, Zeineb Bouzid, Omer T. Inan, Mohammad Nikbakht, Chuoqi Chen
article en

Abstract

Seamless monitoring of vital signs in stranded persons could enhance rescue operations by providing physiological status and prioritizing efforts accordingly. In this work, we explore the feasibility of a skin-contact-free system embedded within life vest for heart rate (HR) and heart rate variability (HRV) monitoring based on ballistocardiogram (BCG). The system is validated using human subject experiments performed both on land and underwater, and at different temperatures, against an electrocardiogram (ECG)-based gold-standard reference. Three different state-of-art processing pipelines were adapted to extract heartbeat timings. Multiple standard metrics were used to assess their performance - the adapted method based on Brüser et al. outperformed two other explored methods. HR correlation coefficients achieved by the best method were 0.92 (baseline on land), 0.90 (cold pressor on land), 0.87 (cold pool), and 0.96 (hot tub) [p < 0.001]. Bland-Altman analysis showed tight limits of agreement (LoA =1.96 SD) across all environments, ranging from 2.37 bpm (hot tub) to 4.95 bpm (cold pressor on land). The detection rate reached ≥67.82% (pool), with a modified efficiency of ≥79.35% (pool). Different HRV metrics in time and frequency domains were calculated. Mean inter-beat intervals (mean IBIs) and standard deviation of successive normal-to-normal intervals (SDNN) outperformed other metrics, in terms of mean absolute error (≤ 12.77 ms and ≤ 16.28 ms, respectively) and LoA (≤ 36.48 ms). This work presents significant progress in underwater cardiac physiology monitoring without ECG, demonstrating the feasibility of a BCG-based monitoring system integrated into a life vest to aid in rescue operations.

IEEE Sensors JournalVol. 25(22)
Georgia Institute of Technology (US), University of Maryland, College Park (US)
Openalex Percentile: Top 72%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.