A stepped-diameter dielectric resonator for simultaneous microwave surface resistance measurement of monolithic double-sided HTS films

Abstract With the widespread application of superconducting thin films in microwave fields and the ongoing development of novel superconducting thin film materials, the precise measurement of surface resistance ( R S ) has become an important challenge. To address issues in traditional dielectric resonator methods, such as the requirement for multiple samples, insufficient sensitivity in nonlinear measurements of single samples, and difficulties in evaluating systematic errors, this paper proposes an improved image resonator measuring device working in the TE 01(1+ δ ) mode at approximately 12 GHz. By designing a stepped-diameter coaxial cylindrical dielectric column structure, the electromagnetic field distribution in the resonant cavity is optimized, substantially enhancing the quality factor of the working mode. This device achieves a sensitivity of 5626 in the quality factor change per 0.01 mΩ variation in R S at a test value of 0.1 mΩ, demonstrating a significant improvement compared to conventional methods. Additionally, a dual-side measuring scheme and an error compensation algorithm are proposed to improve the measuring efficiency for double-sided thin films while effectively quantifying the impact of potential asymmetry between the test and calibration cavities in the image resonator method on measurement accuracy. Experimental results demonstrate that the measurement uncertainty of this device is better than 2%. Combining high sensitivity and efficiency with low systematic errors, this apparatus provides an efficient and reliable solution for microwave surface resistance measurement of single-sided high-temperature superconducting thin films.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-10-13
DOI
https://doi.org/10.1088/1361-6501/ae124b
Primary Topic
Physics of Superconductivity and Magnetism
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A stepped-diameter dielectric resonator for simultaneous microwave surface resistance measurement of monolithic double-sided HTS films

Bowan Tao, Jinxiao Wang, Junsong Ning, Li Luo et al.
Measurement Science and Technology
Physics of Superconductivity and Magnetism
article

A stepped-diameter dielectric resonator for simultaneous microwave surface resistance measurement of monolithic double-sided HTS films

Bowan Tao, Jinxiao Wang, Junsong Ning, Li Luo, Shirong Bu, Xuanwei Wei, Zhanping Wang, Jiwen Lu, Cheng Zeng, Zhicheng Guan
article en

Abstract

Abstract With the widespread application of superconducting thin films in microwave fields and the ongoing development of novel superconducting thin film materials, the precise measurement of surface resistance ( R S ) has become an important challenge. To address issues in traditional dielectric resonator methods, such as the requirement for multiple samples, insufficient sensitivity in nonlinear measurements of single samples, and difficulties in evaluating systematic errors, this paper proposes an improved image resonator measuring device working in the TE 01(1+ δ ) mode at approximately 12 GHz. By designing a stepped-diameter coaxial cylindrical dielectric column structure, the electromagnetic field distribution in the resonant cavity is optimized, substantially enhancing the quality factor of the working mode. This device achieves a sensitivity of 5626 in the quality factor change per 0.01 mΩ variation in R S at a test value of 0.1 mΩ, demonstrating a significant improvement compared to conventional methods. Additionally, a dual-side measuring scheme and an error compensation algorithm are proposed to improve the measuring efficiency for double-sided thin films while effectively quantifying the impact of potential asymmetry between the test and calibration cavities in the image resonator method on measurement accuracy. Experimental results demonstrate that the measurement uncertainty of this device is better than 2%. Combining high sensitivity and efficiency with low systematic errors, this apparatus provides an efficient and reliable solution for microwave surface resistance measurement of single-sided high-temperature superconducting thin films.

Measurement Science and TechnologyVol. 36(10)
University of Electronic Science and Technology of China (CN), Nankai University (CN), National Engineering Research Center of Electromagnetic Radiation Control Materials (CN)
Openalex Percentile: Top 82%
Physics of Superconductivity and Magnetism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.