Achieving high-resolution spatial mapping of dose and linear energy transfer in ion-beam therapy
<i>Objective.</i>We present a novel detector system capable of simultaneously obtaining two-dimensional (2D) dose and linear energy transfer (LET) maps from Al<sub>2</sub>O<sub>3</sub>films of sizes up to(190×190) mm<sup>2</sup>using optically stimulated luminescence (OSL).<i>Approach.</i>The system is based on the OSL from doped Al<sub>2</sub>O<sub>3</sub>films measured using pulsed stimulation and time-resolved OSL detection. The system was calibrated in<sup>1</sup>H-,<sup>4</sup>He-, and<sup>12</sup>C-ion beams. The minimal detectable dose (MDD), response homogeneity, pixel cross-stimulation, and precision were also investigated. To demonstrate the system's performance, 2D maps of dose and LET of a proton Bragg curve were measured.<i>Main results.</i>The system was demonstrated to be capable of obtaining absorbed dose and LET 2D maps with a spatial resolution set to(1.0×1.0) mm<sup>2</sup>. The system was calibrated over a clinically relevant range of LET values and characterized through assessment of MDD (<25 mGy), readout protocols, response homogeneity, precision, and relative detector efficiency. Dose and LET were found to be measurable with precisions of 3.2% and 10%, respectively.<i>Significance.</i>To our knowledge, this is the first passive detector system capable of measuring LET and dose simultaneously in 2D with a 1.0 mm<sup>2</sup>spatial resolution requiring no prior information. Such properties are required to experimentally validate simulated dose and LET distributions in ion-beam therapy, paving the way for sub-mm mapping of radiation-induced relative biological effectiveness.
Authors
- Jeppe Brage Christensen (ORCID: https://orcid.org/0000-0002-6894-381X)
- Stephan Brons (ORCID: https://orcid.org/0000-0002-4695-0816)
- E.G. Yukihara (ORCID: https://orcid.org/0000-0002-4615-6698)
- Iván Domingo Muñoz (ORCID: https://orcid.org/0000-0001-5183-3705)
- Michele Togno (ORCID: https://orcid.org/0000-0001-6840-814X)
- Mads L. Jensen (ORCID: https://orcid.org/0000-0001-9534-9034)
- O. Jaekel (ORCID: https://orcid.org/0000-0002-6056-9747)
Institutions
- German Cancer Research Center (DE)
- Heidelberg University (DE)
- University Hospital Heidelberg (DE)
- Paul Scherrer Institute (CH)
Publication Details
- Journal
- Physics in Medicine and Biology
- Published
- 2025-10-13
- DOI
- https://doi.org/10.1088/1361-6560/ae128f
- Primary Topic
- Radiation Detection and Scintillator Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Science Foundation
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Universitätsspital Zürich