Implantation of Leadless Pacemaker in a Patient With Chronic Type A Aortic Dissection‐A Case Report

When implanted into a structurally normal heart, leadless pacemakers are more effective and safer than traditional pacemakers. However, clinical experience with leadless pacemaker implantation in patients with severe right heart deformity remains limited. We present a rare case of an 87-year-old woman with right heart deformity (secondary to chronic Stanford type A aortic dissection) who successfully underwent implantation of a Micra leadless pacemaker. Preoperative computed tomography (CT) revealed compression of the right atrium by an ascending aortic root dissection aneurysm (maximum diameter: 7.2 cm) and clockwise rotation of the right heart. The delivery system was adjusted repeatedly during the operation, and angiography confirmed that the delivery system was in the right ventricle before releasing the pacemaker. Preoperative familiarity with distorted cardiac anatomy (via CT) and intraoperative angiographic verification of delivery system location are critical for safe leadless pacemaker implantation in patients with right heart deformity. These measures can effectively prevent complications such as cardiac perforation.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2025-10-12
DOI
https://doi.org/10.1002/ccd.70222
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implantation of Leadless Pacemaker in a Patient With Chronic Type A Aortic Dissection‐A Case Report

Xin Zhang, Yue Luo, Xingbin Liu, Xuehui Liu
Catheterization and Cardiovascular Interventions
Cardiac Valve Diseases and Treatments
article

Implantation of Leadless Pacemaker in a Patient With Chronic Type A Aortic Dissection‐A Case Report

Xin Zhang, Yue Luo, Xingbin Liu, Xuehui Liu
article en

Abstract

When implanted into a structurally normal heart, leadless pacemakers are more effective and safer than traditional pacemakers. However, clinical experience with leadless pacemaker implantation in patients with severe right heart deformity remains limited. We present a rare case of an 87-year-old woman with right heart deformity (secondary to chronic Stanford type A aortic dissection) who successfully underwent implantation of a Micra leadless pacemaker. Preoperative computed tomography (CT) revealed compression of the right atrium by an ascending aortic root dissection aneurysm (maximum diameter: 7.2 cm) and clockwise rotation of the right heart. The delivery system was adjusted repeatedly during the operation, and angiography confirmed that the delivery system was in the right ventricle before releasing the pacemaker. Preoperative familiarity with distorted cardiac anatomy (via CT) and intraoperative angiographic verification of delivery system location are critical for safe leadless pacemaker implantation in patients with right heart deformity. These measures can effectively prevent complications such as cardiac perforation.

Catheterization and Cardiovascular InterventionsVol. 106(7)
Sichuan University (CN), West China Hospital of Sichuan University (CN)
Openalex Percentile: Top 57%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.