Calibration of High-Purity Germanium Detector Efficiency Using Standard Charcoal Canister Resources

To determine the activity of radon progeny in the environment, it is necessary to establish a calibration curve for a high-purity germanium (HPGe) detection system using gamma rays in the energy range of 352 keV to 609 keV.Therefore, in this study, gamma radioactive sources with known activity were used to obtain the efficiency calibration curve of the HPGe detector.The sources used in this experiment were charcoal canisters doped with specific activities of radioactive elements such as Eu-152, Ba-133, Cs-137, and Am-241.By calculating the initial activity at the time of source preparation (A0) and knowing the time interval between the preparation of the standard source and its counting in the detector, the current activity of the source was calculated.By measuring the activity of the gamma-emitting sources using the detector and determining the efficiency factor as a function of the energy of each gamma-emitting source, an applicable efficiency equation as a function of gamma-ray energy can be derived, allowing the detector to be calibrated based on the efficiency factor at the desired gammaray energy.

Publication Details

Journal
JOURNAL OF MEDICINE CARE AND HEALTH REVIEW
Published
2025-10-13
DOI
https://doi.org/10.61615/jmchr/2025/oct027141013
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of High-Purity Germanium Detector Efficiency Using Standard Charcoal Canister Resources

JOURNAL OF MEDICINE CARE AND HEALTH REVIEW
Radiation Detection and Scintillator Technologies
article

Calibration of High-Purity Germanium Detector Efficiency Using Standard Charcoal Canister Resources

article en

Abstract

To determine the activity of radon progeny in the environment, it is necessary to establish a calibration curve for a high-purity germanium (HPGe) detection system using gamma rays in the energy range of 352 keV to 609 keV.Therefore, in this study, gamma radioactive sources with known activity were used to obtain the efficiency calibration curve of the HPGe detector.The sources used in this experiment were charcoal canisters doped with specific activities of radioactive elements such as Eu-152, Ba-133, Cs-137, and Am-241.By calculating the initial activity at the time of source preparation (A0) and knowing the time interval between the preparation of the standard source and its counting in the detector, the current activity of the source was calculated.By measuring the activity of the gamma-emitting sources using the detector and determining the efficiency factor as a function of the energy of each gamma-emitting source, an applicable efficiency equation as a function of gamma-ray energy can be derived, allowing the detector to be calibrated based on the efficiency factor at the desired gammaray energy.

JOURNAL OF MEDICINE CARE AND HEALTH REVIEW
Openalex Percentile: Top 61%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Calibration of High-Purity Germanium Detector Efficiency Using Standard Charcoal Canister Resources · JOURNAL OF MEDICINE CARE AND HEALTH REVIEW (2025) | TGRS Research Map | TGRS