Design and Analysis of Non-Invasive Glucometer Using Semi-Cylindrical Capacitive Sensor (SCCS) Based on ATMega328P Microcontroller

This research aims to analyze the reliability of a non-invasive blood glucose detection device (glucometer) based on semi-cylindrical capacitive sensor (SCCS) with ATmega328P microcontroller. The device is designed to measure blood glucose levels non-invasively, without requiring blood sampling. This research uses SCCS to measure the dielectric constant of the finger containing glucose. This dielectric constant is then linked to blood glucose levels through a calibration equation. The calibration equation is obtained from experimental data that links the dielectric constant to blood glucose levels. The ATmega328P microcontroller is used to process signals from the SCCS and calculate blood glucose levels based on the calibration equation. The blood glucose measurement results are displayed on an I2C LCD. The reliability test of this device is carried out by comparing the measurement results with the measurement results of a standard invasive glucometer. The results of the study show that the device has an accuracy of 88.45% close to Invasive glucometer.

Authors

Institutions

Publication Details

Journal
Engineering headway
Published
2025-10-13
DOI
https://doi.org/10.4028/p-gkhse1
Primary Topic
Water Quality Monitoring Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Analysis of Non-Invasive Glucometer Using Semi-Cylindrical Capacitive Sensor (SCCS) Based on ATMega328P Microcontroller

I. Putu Fadya Rachmawan, Muhammad Aulia Alfarisi, Andi Baihaky
Engineering headway
Water Quality Monitoring Technologies
article

Design and Analysis of Non-Invasive Glucometer Using Semi-Cylindrical Capacitive Sensor (SCCS) Based on ATMega328P Microcontroller

I. Putu Fadya Rachmawan, Muhammad Aulia Alfarisi, Andi Baihaky
article en

Abstract

This research aims to analyze the reliability of a non-invasive blood glucose detection device (glucometer) based on semi-cylindrical capacitive sensor (SCCS) with ATmega328P microcontroller. The device is designed to measure blood glucose levels non-invasively, without requiring blood sampling. This research uses SCCS to measure the dielectric constant of the finger containing glucose. This dielectric constant is then linked to blood glucose levels through a calibration equation. The calibration equation is obtained from experimental data that links the dielectric constant to blood glucose levels. The ATmega328P microcontroller is used to process signals from the SCCS and calculate blood glucose levels based on the calibration equation. The blood glucose measurement results are displayed on an I2C LCD. The reliability test of this device is carried out by comparing the measurement results with the measurement results of a standard invasive glucometer. The results of the study show that the device has an accuracy of 88.45% close to Invasive glucometer.

Engineering headwayVol. 27
Universitas Gadjah Mada (ID)
Openalex Percentile: Top 73%
Water Quality Monitoring Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Analysis of Non-Invasive Glucometer Using Semi-Cylindrical Capacitive Sensor (SCCS) Based on ATMega328P Microcontroller — I. Putu Fadya Rachmawan, Muhammad Aulia Alfarisi, et al. · Engineering headway (2025) | TGRS Research Map | TGRS