High-Resolution Subsurface Photoacoustic Imaging of the Teeth Layer

Subsurface photoacoustic imaging with high resolution is utilized to image the teeth layer due to periodontal tissue inflammation. The aim of this imaging method is to determine the difference between healthy teeth and teeth affected by inflammation based on the acoustic signals obtained. An 808 nm diode laser is used as a radiation source, a condenser microphone is used as a detector, and computer numerical control (CNC) is used for the sample scanning process. The samples were healthy and inflamed Sprague-Dawley rat teeth. The average acoustic intensity of healthy teeth layers was 60.200.9 dB for enamel and 52.210.9 dB for dentin, while the average acoustic intensity of inflammation-affected teeth layers was 93.140.4 dB for enamel and 84.840.4 dB for dentin. Based on the histogram results obtained, the generative adversarial network (GAN) method can be used to improve photoacoustic image resolution to become more detailed. The study shows that high-resolution subsurface photoacoustic imaging can be utilized to image teeth layers.

Authors

Institutions

Publication Details

Journal
Engineering headway
Published
2025-10-13
DOI
https://doi.org/10.4028/p-ypx64w
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Resolution Subsurface Photoacoustic Imaging of the Teeth Layer

Rini Widyaningrum, Andreas Setiawan, Atika Windra Sari, Mitrayana Mitrayana
Engineering headway
Photoacoustic and Ultrasonic Imaging
article

High-Resolution Subsurface Photoacoustic Imaging of the Teeth Layer

Rini Widyaningrum, Andreas Setiawan, Atika Windra Sari, Mitrayana Mitrayana
article en

Abstract

Subsurface photoacoustic imaging with high resolution is utilized to image the teeth layer due to periodontal tissue inflammation. The aim of this imaging method is to determine the difference between healthy teeth and teeth affected by inflammation based on the acoustic signals obtained. An 808 nm diode laser is used as a radiation source, a condenser microphone is used as a detector, and computer numerical control (CNC) is used for the sample scanning process. The samples were healthy and inflamed Sprague-Dawley rat teeth. The average acoustic intensity of healthy teeth layers was 60.200.9 dB for enamel and 52.210.9 dB for dentin, while the average acoustic intensity of inflammation-affected teeth layers was 93.140.4 dB for enamel and 84.840.4 dB for dentin. Based on the histogram results obtained, the generative adversarial network (GAN) method can be used to improve photoacoustic image resolution to become more detailed. The study shows that high-resolution subsurface photoacoustic imaging can be utilized to image teeth layers.

Engineering headwayVol. 27
Satya Wacana Christian University (ID), Universitas Gadjah Mada (ID)
Openalex Percentile: Top 72%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.