Development of a PLC-Based Kartini Reactor Operation Data Acquisition System

The development of data acquisition system for operation of the Kartini reactor was carried out by using a programable-logic controller (PLC) and based on the recommendation of an expert team of the International Atomic Energy Agency which justifies that the previous data acquisition system of the reactor operation has been considered obsolete. This research purpose is to follow up the recommendation by using a recent technology of PLC as the basis of the system. The parameter acquisition method was done by acquiring the analogue and digital voltage signals by the PLC and processing them into values accordingly. Analogue parameters: linear power, logarithmic power percent, period, and three control bars, Digital parameters: trigger trip signals. Parameter values are visually displayed using LabVIEW. The test method was comparing the obtained values to the current monitoring subsystem. Test results: linear power error is 0.09%; period error is 0.8%; and error of the three control rods is below 1%. All digital signal test results successfully show appropriate trip conditions when active. The conclusion of this study is successful in making a design of the Kartini Reactor process parameter acquisition system with small relative errors to the existing system.

Authors

Institutions

Publication Details

Journal
Engineering headway
Published
2025-10-13
DOI
https://doi.org/10.4028/p-rp37bb
Primary Topic
Advanced Data Processing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a PLC-Based Kartini Reactor Operation Data Acquisition System

Sutanto Sutanto, Muhammad Salino Akbar, Zulfikar Elran Bhagaskara
Engineering headway
Advanced Data Processing Techniques
article

Development of a PLC-Based Kartini Reactor Operation Data Acquisition System

Sutanto Sutanto, Muhammad Salino Akbar, Zulfikar Elran Bhagaskara
article en

Abstract

The development of data acquisition system for operation of the Kartini reactor was carried out by using a programable-logic controller (PLC) and based on the recommendation of an expert team of the International Atomic Energy Agency which justifies that the previous data acquisition system of the reactor operation has been considered obsolete. This research purpose is to follow up the recommendation by using a recent technology of PLC as the basis of the system. The parameter acquisition method was done by acquiring the analogue and digital voltage signals by the PLC and processing them into values accordingly. Analogue parameters: linear power, logarithmic power percent, period, and three control bars, Digital parameters: trigger trip signals. Parameter values are visually displayed using LabVIEW. The test method was comparing the obtained values to the current monitoring subsystem. Test results: linear power error is 0.09%; period error is 0.8%; and error of the three control rods is below 1%. All digital signal test results successfully show appropriate trip conditions when active. The conclusion of this study is successful in making a design of the Kartini Reactor process parameter acquisition system with small relative errors to the existing system.

Engineering headwayVol. 27
National Research, Development and Innovation Office (HU), National Research and Innovation Agency (ID)
Openalex Percentile: Top 63%
Advanced Data Processing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.