Novel Reactor for In Situ Dielectric Constant Measurements of Fluids at High Temperature and Pressure

The dielectric constant measures the influence of an electric field on a material. As it probes solute–solvent interactions within a fluid, it could shed light on reactions such as the hydrothermal conversion of biomass to biofuels. However, such measurements are difficult to obtain due to the low temperature and electrical conductivity operating limits of conventional dielectric constant apparati. An apparatus was designed to measure the dielectric constant of fluids up to 220 °C consisting of a cylindrical resonant cavity that operates in TM010 mode at 1 GHz. The liquid sample is contained in a bespoke quartz tube reactor with an internal thermocouple and a pressure transducer. The sample temperature is manipulated with a dual zone heating unit. The system was validated with pure subcritical water between 20 to 220 °C and was employed to in situ detect changes in the dielectric constant of five organic solvents up to 200 °C, beyond values currently available in the literature. The maximum deviation from reference data is approximately 5% for water. The maximum deviation extends to 20% with less polar organic solvents when compared to values using single-Debye models in high-temperature regions.

Authors

Institutions

Publication Details

Journal
Journal of Chemical & Engineering Data
Published
2025-10-13
DOI
https://doi.org/10.1021/acs.jced.5c00373
Primary Topic
Thermodynamic properties of mixtures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Reactor for In Situ Dielectric Constant Measurements of Fluids at High Temperature and Pressure

Jillian L. Goldfarb, San Lin Htun
Journal of Chemical & Engineering Data
Thermodynamic properties of mixtures
article

Novel Reactor for In Situ Dielectric Constant Measurements of Fluids at High Temperature and Pressure

Jillian L. Goldfarb, San Lin Htun
article en

Abstract

The dielectric constant measures the influence of an electric field on a material. As it probes solute–solvent interactions within a fluid, it could shed light on reactions such as the hydrothermal conversion of biomass to biofuels. However, such measurements are difficult to obtain due to the low temperature and electrical conductivity operating limits of conventional dielectric constant apparati. An apparatus was designed to measure the dielectric constant of fluids up to 220 °C consisting of a cylindrical resonant cavity that operates in TM010 mode at 1 GHz. The liquid sample is contained in a bespoke quartz tube reactor with an internal thermocouple and a pressure transducer. The sample temperature is manipulated with a dual zone heating unit. The system was validated with pure subcritical water between 20 to 220 °C and was employed to in situ detect changes in the dielectric constant of five organic solvents up to 200 °C, beyond values currently available in the literature. The maximum deviation from reference data is approximately 5% for water. The maximum deviation extends to 20% with less polar organic solvents when compared to values using single-Debye models in high-temperature regions.

Journal of Chemical & Engineering DataVol. 70(11)
Cornell University (US)
Openalex Percentile: Top 74%
Thermodynamic properties of mixtures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.