Exploring the fluorinome of PFAS-impacted groundwater using 21 tesla FT-ICR mass spectrometry

Non-targeted analysis of complex per- and polyfluoroalkyl substances (PFAS) via Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR MS) promises unprecedented insights into the "fluorinome", i.e., the complete set of organofluorine compounds in a given sample. In this study, we present a Python-based workflow developed in parallel with a carefully constructed PFAS formula database comprising ∼ 20 million entries to facilitate the assignment of chemical formulas to ultrahigh-resolution mass spectra. PFAS assignments based on the analysis of complex aqueous film-forming foam (AFFF) on the world's highest-resolving 21 tesla FT-ICR MS were compared to quadrupole time-of-flight (QTOF) MS data, validating 22 common and discovering 19 previously undetected PFAS classes. We then explored the viability of ultrahigh-resolution FT-ICR MS analysis for forensic profiling purposes on PFAS-impacted groundwater samples, identifying bis-perfluoroalkyl sulfonimides (bis-FASIs) as long-suspected ingredients of electrochemical fluorination AFFFs. While our newly developed workflow may also be used for other types of high-resolution mass spectrometers such as QTOF and Orbitrap, this work leverages the unique ultrahigh-resolving power, sub-ppm mass measurement accuracy, and high dynamic range of 21 tesla FT-ICR mass spectrometry to maximize information from complex contaminant mixtures in environmental samples.

Authors

Institutions

Publication Details

Journal
Water Research
Published
2025-09-29
DOI
https://doi.org/10.1016/j.watres.2025.124698
Citations
1
Primary Topic
Mercury impact and mitigation studies
Type
article
Field-Weighted Citation Impact
1.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring the fluorinome of PFAS-impacted groundwater using 21 tesla FT-ICR mass spectrometry

Amy M. McKenna, Jens Blotevogel, Shilai Hao, Christopher P. Higgins et al.
1 citations
Water Research
Mercury impact and mitigation studies
1.20
article

Exploring the fluorinome of PFAS-impacted groundwater using 21 tesla FT-ICR mass spectrometry

Amy M. McKenna, Jens Blotevogel, Shilai Hao, Christopher P. Higgins, Lydia Babcock‐Adams, Robert B. Young, Hamidreza Sharifan, John J. Kornuc, Wenchao Lu
article en
1 citations

Abstract

Non-targeted analysis of complex per- and polyfluoroalkyl substances (PFAS) via Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR MS) promises unprecedented insights into the "fluorinome", i.e., the complete set of organofluorine compounds in a given sample. In this study, we present a Python-based workflow developed in parallel with a carefully constructed PFAS formula database comprising ∼ 20 million entries to facilitate the assignment of chemical formulas to ultrahigh-resolution mass spectra. PFAS assignments based on the analysis of complex aqueous film-forming foam (AFFF) on the world's highest-resolving 21 tesla FT-ICR MS were compared to quadrupole time-of-flight (QTOF) MS data, validating 22 common and discovering 19 previously undetected PFAS classes. We then explored the viability of ultrahigh-resolution FT-ICR MS analysis for forensic profiling purposes on PFAS-impacted groundwater samples, identifying bis-perfluoroalkyl sulfonimides (bis-FASIs) as long-suspected ingredients of electrochemical fluorination AFFFs. While our newly developed workflow may also be used for other types of high-resolution mass spectrometers such as QTOF and Orbitrap, this work leverages the unique ultrahigh-resolving power, sub-ppm mass measurement accuracy, and high dynamic range of 21 tesla FT-ICR mass spectrometry to maximize information from complex contaminant mixtures in environmental samples.

Water ResearchVol. 288(Pt B)
New Mexico State University (US), Florida State University (US), Commonwealth Scientific and Industrial Research Organisation (AU), The University of Texas at El Paso (US), Colorado School of Mines (US), Naval Facilities Engineering Systems Command (US), National High Magnetic Field Laboratory (US)
Openalex Percentile: Top 17%
Mercury impact and mitigation studies
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.