In-Capillary Chemoselective Tagging-Facilitated Direct nESI-MS Profiling of Carboxyl- and Carbonyl-Containing Metabolites in Urine

Carboxyl- and carbonyl-containing metabolites (CCMs) are essential for energy metabolism and signaling in living cells and can serve as diagnostic biomarkers for various diseases. However, their low ESI ionization efficiencies and structural diversities could bring difficulties for their direct detection by mass spectrometry. In this work, a chemoselective tagging and acid-trigged release (CTAR) strategy-based nanoelectrospray ionization-mass spectrometry (nESI-MS) platform was developed by immobilizing a cis-diol-containing amine probe (i.e., 3-((2-aminoethyl)amino)propane-1,2-diol, denoted as AEAP-diol) on a coated ESI capillary with boronate esters as acid cleavage site, which can directly and selectively "fish out" targeted CCMs from biological matrices. Following the removal of unwanted species, the AEAP-diol tagged CCMs derivatives can be online released and directly detected by nESI-MS within 1 min. MS/MS fragmentation profiles of these CCMs derivatives exhibited a neutral loss of 91 Da and diagnostic fragments at <i>m</i>/<i>z</i> 118 for carboxyl- and carbonyl-containing metabolites, respectively, thereby enabling unambiguous structural elucidation of unknown CCMs. With high specificity, superior salt tolerance, and outstanding robustness, our CTAR-nESI-MS platform enabled direct and sensitive analysis of CCMs from a single drop of biofluid (2.5 μL of urine), achieving a low detection limit of 0.1 ppb for butyric acid. Using this method, 26 carboxyl- and carbonyl-containing metabolites were identified and quantified in urine samples from esophageal cancer patients and healthy volunteers, revealing significant differences in several reported CCM biomarkers. These findings collectively underscore the potential of CTAR-nESI-MS as a sensitive, cost-effective, and versatile tool for comprehensive metabolite profiling and high-throughput screening applications.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-10-13
DOI
https://doi.org/10.1021/acs.analchem.5c04351
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-Capillary Chemoselective Tagging-Facilitated Direct nESI-MS Profiling of Carboxyl- and Carbonyl-Containing Metabolites in Urine

Xiaobo Xie, Chengbo Mou, Yi Lv, Zili Huang et al.
Analytical Chemistry
Mass Spectrometry Techniques and Applications
article

In-Capillary Chemoselective Tagging-Facilitated Direct nESI-MS Profiling of Carboxyl- and Carbonyl-Containing Metabolites in Urine

Xiaobo Xie, Chengbo Mou, Yi Lv, Zili Huang, Xiumei Zheng, Yifan Wei
article en

Abstract

Carboxyl- and carbonyl-containing metabolites (CCMs) are essential for energy metabolism and signaling in living cells and can serve as diagnostic biomarkers for various diseases. However, their low ESI ionization efficiencies and structural diversities could bring difficulties for their direct detection by mass spectrometry. In this work, a chemoselective tagging and acid-trigged release (CTAR) strategy-based nanoelectrospray ionization-mass spectrometry (nESI-MS) platform was developed by immobilizing a cis-diol-containing amine probe (i.e., 3-((2-aminoethyl)amino)propane-1,2-diol, denoted as AEAP-diol) on a coated ESI capillary with boronate esters as acid cleavage site, which can directly and selectively "fish out" targeted CCMs from biological matrices. Following the removal of unwanted species, the AEAP-diol tagged CCMs derivatives can be online released and directly detected by nESI-MS within 1 min. MS/MS fragmentation profiles of these CCMs derivatives exhibited a neutral loss of 91 Da and diagnostic fragments at <i>m</i>/<i>z</i> 118 for carboxyl- and carbonyl-containing metabolites, respectively, thereby enabling unambiguous structural elucidation of unknown CCMs. With high specificity, superior salt tolerance, and outstanding robustness, our CTAR-nESI-MS platform enabled direct and sensitive analysis of CCMs from a single drop of biofluid (2.5 μL of urine), achieving a low detection limit of 0.1 ppb for butyric acid. Using this method, 26 carboxyl- and carbonyl-containing metabolites were identified and quantified in urine samples from esophageal cancer patients and healthy volunteers, revealing significant differences in several reported CCM biomarkers. These findings collectively underscore the potential of CTAR-nESI-MS as a sensitive, cost-effective, and versatile tool for comprehensive metabolite profiling and high-throughput screening applications.

Analytical ChemistryVol. 97(41)
University of Electronic Science and Technology of China (CN), Sichuan University (CN), Analysis and Testing Centre (CN), North China University of Science and Technology Affiliated Hospital (CN), Sichuan Cancer Hospital (CN), Green Chemistry (PL)
Openalex Percentile: Top 73%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.