A Novel C-terminal Sequence Variant Discovered in an IgG1 Monoclonal Antibody by LC-MS

Sequence variant analysis is critical for characterizing biologic therapeutics and ensuring product quality, consistency, and safety. During routine tryptic peptide mapping of an IgG1 monoclonal antibody therapeutic, we identified a novel variant with a +113 Da mass shift at the heavy chain C-terminus. This variant was present at an unusually high abundance of up to 1.5%. The initial hypotheses suggested a leucine/isoleucine (Leu/Ile) addition; however, HCD multistage tandem mass spectrometry revealed an unexpected two-amino acid substitution (Val-Ala). A synthetic peptide with the hypothesized sequence confirmed this novel sequence variant, exhibiting identical retention time and fragmentation patterns. Further investigation suggested aberrant mRNA splicing, involving a cryptic splice site near glycine-encoding codons in the expression constructs, as a potential underlying mechanism. These findings demonstrate the importance of high-resolution mass spectrometry and alternate fragmentation methods for resolving isobaric ambiguities and highlight the influence of codon optimization on sequence variant profiles.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-10-13
DOI
https://doi.org/10.1021/jasms.5c00208
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel C-terminal Sequence Variant Discovered in an IgG1 Monoclonal Antibody by LC-MS

Tawnya G. Flick, Douglas S. Rehder, Simon Letarte, Miyang Li et al.
Journal of the American Society for Mass Spectrometry
Protein purification and stability
article

A Novel C-terminal Sequence Variant Discovered in an IgG1 Monoclonal Antibody by LC-MS

Tawnya G. Flick, Douglas S. Rehder, Simon Letarte, Miyang Li, Bo Jiang, Huong Thi Thanh Le, Oliver Silerio
article en

Abstract

Sequence variant analysis is critical for characterizing biologic therapeutics and ensuring product quality, consistency, and safety. During routine tryptic peptide mapping of an IgG1 monoclonal antibody therapeutic, we identified a novel variant with a +113 Da mass shift at the heavy chain C-terminus. This variant was present at an unusually high abundance of up to 1.5%. The initial hypotheses suggested a leucine/isoleucine (Leu/Ile) addition; however, HCD multistage tandem mass spectrometry revealed an unexpected two-amino acid substitution (Val-Ala). A synthetic peptide with the hypothesized sequence confirmed this novel sequence variant, exhibiting identical retention time and fragmentation patterns. Further investigation suggested aberrant mRNA splicing, involving a cryptic splice site near glycine-encoding codons in the expression constructs, as a potential underlying mechanism. These findings demonstrate the importance of high-resolution mass spectrometry and alternate fragmentation methods for resolving isobaric ambiguities and highlight the influence of codon optimization on sequence variant profiles.

Journal of the American Society for Mass SpectrometryVol. 36(11)
Gilead Sciences (United States) (US)
Openalex Percentile: Top 75%
Protein purification and stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel C-terminal Sequence Variant Discovered in an IgG1 Monoclonal Antibody by LC-MS — Tawnya G. Flick, Douglas S. Rehder, et al. · Journal of the American Society for Mass Spectrometry (2025) | TGRS Research Map | TGRS