Comparison of microcapillary column length and inner diameter investigated with gradient analysis of lipids by ultrahigh‐pressure liquid chromatography‐mass spectrometry

Biological samples in lipidomic studies can consist of extremely complex mixtures due to the diverse range of species and isomerism. Herein, highly efficient, in-house packed microcapillary columns introduce the potential to better separate these complex mixtures. We compared the effects of changing column length (15, 30, and 60 cm) and inner diameter (75 and 100 μm) on lipid separation efficiency by reversed-phase gradient analysis using ultrahigh-pressure liquid chromatography coupled to mass spectrometry with operating pressures ranging from 450 to 2200 bar. Seven lipid standards composed of phosphatidylcholine and triacylglycerol species were analyzed at four different gradient rates to calculate conditional peak capacity. The longest column, 60 cm, at the shallowest gradient of 2% gave the highest peak capacity of 359 with a separation window of 2 h. The intermediate column length of 30 cm with 75 μm inner diameter provided a peak capacity of 287 with a separation window of 1 h. There was no significant difference in peak capacity between 75 and 100 μm inner diameter columns. This study showed that using highly efficient microcapillary columns increased peak capacity and resolution of lipids, and thus, this technique seems promising for enhancing lipid coverage and enabling better discovery of lipid biomarkers.

Authors

Institutions

Publication Details

Journal
UNC Libraries
Published
2025-10-11
DOI
https://doi.org/10.17615/qj24-ab28
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of microcapillary column length and inner diameter investigated with gradient analysis of lipids by ultrahigh‐pressure liquid chromatography‐mass spectrometry

James W. Jorgenson, Kelsey E. Miller
UNC Libraries
Analytical Chemistry and Chromatography
article

Comparison of microcapillary column length and inner diameter investigated with gradient analysis of lipids by ultrahigh‐pressure liquid chromatography‐mass spectrometry

James W. Jorgenson, Kelsey E. Miller
article en

Abstract

Biological samples in lipidomic studies can consist of extremely complex mixtures due to the diverse range of species and isomerism. Herein, highly efficient, in-house packed microcapillary columns introduce the potential to better separate these complex mixtures. We compared the effects of changing column length (15, 30, and 60 cm) and inner diameter (75 and 100 μm) on lipid separation efficiency by reversed-phase gradient analysis using ultrahigh-pressure liquid chromatography coupled to mass spectrometry with operating pressures ranging from 450 to 2200 bar. Seven lipid standards composed of phosphatidylcholine and triacylglycerol species were analyzed at four different gradient rates to calculate conditional peak capacity. The longest column, 60 cm, at the shallowest gradient of 2% gave the highest peak capacity of 359 with a separation window of 2 h. The intermediate column length of 30 cm with 75 μm inner diameter provided a peak capacity of 287 with a separation window of 1 h. There was no significant difference in peak capacity between 75 and 100 μm inner diameter columns. This study showed that using highly efficient microcapillary columns increased peak capacity and resolution of lipids, and thus, this technique seems promising for enhancing lipid coverage and enabling better discovery of lipid biomarkers.

UNC Libraries
University of North Carolina at Chapel Hill (US)
Openalex Percentile: Top 73%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.