[Safety and efficacy of aspheric phakic IOL implantation in myopia: short-term clinical results].

<b>Objective:</b> To evaluate the clinical safety and efficacy of aspheric phakic intraocular lens (PIOL) implantation for myopia correction. <b>Methods:</b> This prospective, multicenter, single-blind (patient-masked), randomized, controlled clinical trial was conducted from March 2019 to April 2022 across nine ophthalmic centers (including the Eye & ENT Hospital of Fudan University and Beijing Tongren Hospital, Capital Medical University). Eligible myopic patients scheduled for PIOL implantation were randomly assigned via a centralized dynamic randomization system to receive either the experimental aspheric PR PIOL or the control V4c implantable Collamer lens. At postoperative 1, 3, and 6 months, the efficacy index (primary endpoint: proportion achieving≥0.8 at 6 months), safety index, uncorrected distance/near visual acuity, best-corrected distance visual acuity, vault, intraocular pressure, corneal endothelial cell density, visual symptoms, and complications of the two groups were compared, with statistical analyses using the independent <i>t</i>-tests and chi-square tests. <b>Results:</b> The study enrolled 187 myopic patients (187 eyes), including 47 males (47 eyes) and 140 females (140 eyes), with a mean age of (28.60±5.08) years (range: 25 to 32 years). The experimental group included 91 patients, while the control group included 96 patients. At 6 months postoperatively, the efficacy index was 1.12±0.24 and 1.14±0.21, and the safety index was 1.28±0.26 and 1.26±0.23 in the experimental group and the control group, respectively, with no statistically significant differences between the two groups (both <i>P</i>>0.05). The difference in primary endpoint achievement rates was -1.19% [98.81% (83/84) in the experimental group <i>vs.</i> 100% (86/86) in controls], which exceeded the non-inferiority margin of -10%, demonstrating non-inferiority of the experimental intervention. At 6 months, the experimental group demonstrated uncorrected distance visual acuity of -0.01±0.09 logMAR compared to -0.03±0.08 logMAR in the control group, while best-corrected distance visual acuity was measured at -0.06±0.07 logMAR versus -0.08±0.06 logMAR, with no statistically significant differences observed between groups (both <i>P</i>>0.05). Similarly, there were no statistically significant intergroup differences in intraocular pressure and corneal endothelial cell density (both <i>P</i>>0.05). At both 1 month and 6 months postoperatively, the differences were significant between the two groups in the central vault and the peripheral-central vault difference (all <i>P</i><0.05); however, no statistically significant difference in the peripheral vault was observed between groups (both <i>P</i>>0.05). At 1 month postoperatively, the incidence of glare in the experimental group [24.72% (22/89)] was significantly lower than that in the control group [54.26% (51/94)] (<i>P</i><0.05). And there were no statistically significant differences between the two groups in the incidence of other visual symptoms including diplopia, ghosting, and blurred vision (all <i>P</i>>0.05). During the 6-month follow-up period, neither group exhibited any postoperative complications. <b>Conclusion:</b> Aspheric PIOL implantation shows favorable 6-month safety/efficacy and visual quality in myopia correction, though long-term outcomes warrant further investigations.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-10-11
DOI
https://doi.org/10.3760/cma.j.cn112142-20250421-00192
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Safety and efficacy of aspheric phakic IOL implantation in myopia: short-term clinical results].

Yuwei Yang, Yu Xiong, Q S Zhang, Yan Luo et al.
PubMed
Corneal surgery and disorders
article

[Safety and efficacy of aspheric phakic IOL implantation in myopia: short-term clinical results].

Yuwei Yang, Yu Xiong, Q S Zhang, Yan Luo, Lize Xiong, X Y Wang, Zuobin Wang, Lei Liu, Yanping Li, Zhe Dong, Guangbin Zhang, Xueying Zhou, N L Wang, Daniel C.-H. Lin
article en

Abstract

<b>Objective:</b> To evaluate the clinical safety and efficacy of aspheric phakic intraocular lens (PIOL) implantation for myopia correction. <b>Methods:</b> This prospective, multicenter, single-blind (patient-masked), randomized, controlled clinical trial was conducted from March 2019 to April 2022 across nine ophthalmic centers (including the Eye & ENT Hospital of Fudan University and Beijing Tongren Hospital, Capital Medical University). Eligible myopic patients scheduled for PIOL implantation were randomly assigned via a centralized dynamic randomization system to receive either the experimental aspheric PR PIOL or the control V4c implantable Collamer lens. At postoperative 1, 3, and 6 months, the efficacy index (primary endpoint: proportion achieving≥0.8 at 6 months), safety index, uncorrected distance/near visual acuity, best-corrected distance visual acuity, vault, intraocular pressure, corneal endothelial cell density, visual symptoms, and complications of the two groups were compared, with statistical analyses using the independent <i>t</i>-tests and chi-square tests. <b>Results:</b> The study enrolled 187 myopic patients (187 eyes), including 47 males (47 eyes) and 140 females (140 eyes), with a mean age of (28.60±5.08) years (range: 25 to 32 years). The experimental group included 91 patients, while the control group included 96 patients. At 6 months postoperatively, the efficacy index was 1.12±0.24 and 1.14±0.21, and the safety index was 1.28±0.26 and 1.26±0.23 in the experimental group and the control group, respectively, with no statistically significant differences between the two groups (both <i>P</i>>0.05). The difference in primary endpoint achievement rates was -1.19% [98.81% (83/84) in the experimental group <i>vs.</i> 100% (86/86) in controls], which exceeded the non-inferiority margin of -10%, demonstrating non-inferiority of the experimental intervention. At 6 months, the experimental group demonstrated uncorrected distance visual acuity of -0.01±0.09 logMAR compared to -0.03±0.08 logMAR in the control group, while best-corrected distance visual acuity was measured at -0.06±0.07 logMAR versus -0.08±0.06 logMAR, with no statistically significant differences observed between groups (both <i>P</i>>0.05). Similarly, there were no statistically significant intergroup differences in intraocular pressure and corneal endothelial cell density (both <i>P</i>>0.05). At both 1 month and 6 months postoperatively, the differences were significant between the two groups in the central vault and the peripheral-central vault difference (all <i>P</i><0.05); however, no statistically significant difference in the peripheral vault was observed between groups (both <i>P</i>>0.05). At 1 month postoperatively, the incidence of glare in the experimental group [24.72% (22/89)] was significantly lower than that in the control group [54.26% (51/94)] (<i>P</i><0.05). And there were no statistically significant differences between the two groups in the incidence of other visual symptoms including diplopia, ghosting, and blurred vision (all <i>P</i>>0.05). During the 6-month follow-up period, neither group exhibited any postoperative complications. <b>Conclusion:</b> Aspheric PIOL implantation shows favorable 6-month safety/efficacy and visual quality in myopia correction, though long-term outcomes warrant further investigations.

PubMedVol. 61(10)
Beijing Tongren Hospital (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), He Eye Hospital (CN), Tongji Hospital (CN), Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 57%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.