Electronic transport in three-atom-thick gold nanocontacts: Revealing atomic geometries and applications

We present an in-depth study of electronic transport in atomic-sized gold contacts using Break-Junction (BJ) techniques under cryogenic and ambient conditions. Our experimental results, supported by classical molecular dynamics (CMD) simulations and ab initio calculations, provide compelling evidence for the formation of three-atom-thick structures in gold nanocontacts under tensile stress. These findings extend previous studies that confirmed the existence of one- and two-atom-thick chains. Beyond identifying these novel atomic configurations, we introduce a fast and robust calibration method for Break-Junction systems, leveraging the characteristic length of these structures to convert piezo-distance into absolute distance in angstroms. Our approach presents a novel and robust method for calibrating atomic distances in atomic conductor systems at both cryogenic and room temperatures. The results also enable the assessment of electrode sharpness, even under ambient conditions.

Authors

Institutions

Publication Details

Journal
Physical Review Materials
Published
2026-03-16
DOI
https://doi.org/10.1103/3z2q-cm7x
Primary Topic
Advanced Materials Characterization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electronic transport in three-atom-thick gold nanocontacts: Revealing atomic geometries and applications

Carlos Sabater, F. Guzmán, Juan Cuenca, T. de Ara et al.
Physical Review Materials
Advanced Materials Characterization Techniques
article

Electronic transport in three-atom-thick gold nanocontacts: Revealing atomic geometries and applications

Carlos Sabater, F. Guzmán, Juan Cuenca, T. de Ara, A. Martinez-García
article en

Abstract

We present an in-depth study of electronic transport in atomic-sized gold contacts using Break-Junction (BJ) techniques under cryogenic and ambient conditions. Our experimental results, supported by classical molecular dynamics (CMD) simulations and ab initio calculations, provide compelling evidence for the formation of three-atom-thick structures in gold nanocontacts under tensile stress. These findings extend previous studies that confirmed the existence of one- and two-atom-thick chains. Beyond identifying these novel atomic configurations, we introduce a fast and robust calibration method for Break-Junction systems, leveraging the characteristic length of these structures to convert piezo-distance into absolute distance in angstroms. Our approach presents a novel and robust method for calibrating atomic distances in atomic conductor systems at both cryogenic and room temperatures. The results also enable the assessment of electrode sharpness, even under ambient conditions.

Physical Review MaterialsVol. 10(3)
University of Alicante (ES), École Polytechnique Fédérale de Lausanne (CH)
Openalex Percentile: Top 100%
Advanced Materials Characterization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.