Optimal Frequency Control of Multi Area Power System Under Restructured Environment

This paper presents the intend of a Tilt Integral Derivative (TID) controller for addressing the Load Frequency Control (LFC) issue in a multi-area restructured electric power system. The recommended TID controller configurations are refined by means of a narrative methodology known as the Hunger Games Search (HGS) algorithm. A multi-area electric power system including different producing units is worn to assess the efficacy of the anticipated TID controller based on HGS. The effectiveness of HGS's optimization has been confirmed to surpass that of other prominent optimization techniques, such as the Slime Mould and Artificial Gorilla Troop algorithms. The simulation outcome demonstrates that the anticipated TID controller using HGS markedly improves system frequency constancy underneath diverse load interruption scenarios.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical and Electronics Research
Published
2025-09-30
DOI
https://doi.org/10.37391/ijeer.130320
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Frequency Control of Multi Area Power System Under Restructured Environment

Mohan Yama, Sambugari Anil Kumar, Venkata Subba Reddy Gangireddygari, AileniAmarender Reddy et al.
International Journal of Electrical and Electronics Research
Frequency Control in Power Systems
article

Optimal Frequency Control of Multi Area Power System Under Restructured Environment

Mohan Yama, Sambugari Anil Kumar, Venkata Subba Reddy Gangireddygari, AileniAmarender Reddy, Vuyyuru Anantha Lakshmi
article en

Abstract

This paper presents the intend of a Tilt Integral Derivative (TID) controller for addressing the Load Frequency Control (LFC) issue in a multi-area restructured electric power system. The recommended TID controller configurations are refined by means of a narrative methodology known as the Hunger Games Search (HGS) algorithm. A multi-area electric power system including different producing units is worn to assess the efficacy of the anticipated TID controller based on HGS. The effectiveness of HGS's optimization has been confirmed to surpass that of other prominent optimization techniques, such as the Slime Mould and Artificial Gorilla Troop algorithms. The simulation outcome demonstrates that the anticipated TID controller using HGS markedly improves system frequency constancy underneath diverse load interruption scenarios.

International Journal of Electrical and Electronics ResearchVol. 13(3)
G Pulla Reddy Dental College & Hospital (IN)
Openalex Percentile: Top 72%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimal Frequency Control of Multi Area Power System Under Restructured Environment — Mohan Yama, Sambugari Anil Kumar, et al. · International Journal of Electrical and Electronics Research (2025) | TGRS Research Map | TGRS