The TEG6s-Derived R ratio accurately reflects the anti-Xa level after cardiac surgery: A proof-of-concept study

IntroductionIn the postoperative intensive care setting after cardiac surgery with cardiopulmonary bypass (CPB), particularly in patients requiring continued anticoagulation for prosthetic devices such as mechanical valves or extracorporeal support, unfractionated heparin (UFH) is commonly monitored using the activated partial thromboplastin time (aPTT). However, it may inadequately reflect anticoagulant activity in critically ill patients. The TEG6s system is a viscoelastic testing platform that enables bedside coagulation monitoring. This proof-of-concept study aimed to evaluate the utility of TEG6s-derived indices for estimating the anti-Xa level following CPB.MethodsWe prospectively enrolled 131 adult patients undergoing elective cardiac or aortic surgery with CPB. Paired blood samples were collected at intensive care unit admission and 4 h later. Heparin concentrations were measured using a chromogenic anti-Xa assay. Thromboelastography (TEG) parameters including the reaction times for the citrated kaolin without and with heparinase assays and their ratio (R ratio) and difference were obtained. Their correlations with the anti-Xa level were assessed using Pearson's and Spearman's analyses. Linear and polynomial regression models were used to evaluate predictive performance.ResultsThe R ratio and reaction time difference showed strong correlations with the plasma anti-Xa level (r = 0.738 and r = 0.733, respectively; <i>p</i> < 0.001). These correlations were comparable to that of the aPTT ratio (r = 0.813). The second-order polynomial regression model using the R ratio had the highest predictive accuracy (R<sup>2</sup> = 0.584, root mean square error = 0.134).ConclusionsThe R ratio may be a supplementary indicator of a residual heparin effect, particularly in cases with discordant aPTT findings.

Authors

Institutions

Publication Details

Journal
Perfusion
Published
2025-10-09
DOI
https://doi.org/10.1177/02676591251388353
Citations
1
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
1.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The TEG6s-Derived R ratio accurately reflects the anti-Xa level after cardiac surgery: A proof-of-concept study

Takahiro Tamura, Tatsuro Yokoyama
1 citations
Perfusion
Trauma, Hemostasis, Coagulopathy, Resuscitation
1.55
article

The TEG6s-Derived R ratio accurately reflects the anti-Xa level after cardiac surgery: A proof-of-concept study

Takahiro Tamura, Tatsuro Yokoyama
article en
1 citations

Abstract

IntroductionIn the postoperative intensive care setting after cardiac surgery with cardiopulmonary bypass (CPB), particularly in patients requiring continued anticoagulation for prosthetic devices such as mechanical valves or extracorporeal support, unfractionated heparin (UFH) is commonly monitored using the activated partial thromboplastin time (aPTT). However, it may inadequately reflect anticoagulant activity in critically ill patients. The TEG6s system is a viscoelastic testing platform that enables bedside coagulation monitoring. This proof-of-concept study aimed to evaluate the utility of TEG6s-derived indices for estimating the anti-Xa level following CPB.MethodsWe prospectively enrolled 131 adult patients undergoing elective cardiac or aortic surgery with CPB. Paired blood samples were collected at intensive care unit admission and 4 h later. Heparin concentrations were measured using a chromogenic anti-Xa assay. Thromboelastography (TEG) parameters including the reaction times for the citrated kaolin without and with heparinase assays and their ratio (R ratio) and difference were obtained. Their correlations with the anti-Xa level were assessed using Pearson's and Spearman's analyses. Linear and polynomial regression models were used to evaluate predictive performance.ResultsThe R ratio and reaction time difference showed strong correlations with the plasma anti-Xa level (r = 0.738 and r = 0.733, respectively; <i>p</i> < 0.001). These correlations were comparable to that of the aPTT ratio (r = 0.813). The second-order polynomial regression model using the R ratio had the highest predictive accuracy (R<sup>2</sup> = 0.584, root mean square error = 0.134).ConclusionsThe R ratio may be a supplementary indicator of a residual heparin effect, particularly in cases with discordant aPTT findings.

Perfusion
Nagoya University (JP)
Openalex Percentile: Top 14%
Trauma, Hemostasis, Coagulopathy, Resuscitation
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.