<i>In vivo</i> dynamic optical coherence tomography of human skin with hardware- and software-based motion correction

In vivo application of dynamic optical coherence tomography (DOCT) is hindered by bulk motion of the sample. We demonstrate DOCT imaging of in vivo human skin by adopting a sample-fixation attachment to suppress bulk motion and a subsequent software motion correction to further reduce the effect of sample motion. The performance of the motion-correction method was assessed by DOCT image observation, statistical analysis of the mean DOCT values, and subjective image grading. Both the mean DOCT value analysis and subjective grading showed statistically significant improvement of the DOCT image quality. In addition, a previously unobserved high DOCT layer was identified though image observation, which may represent the stratum basale with high keratinocyte proliferation.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2026-02-10
DOI
https://doi.org/10.1364/boe.588691
Citations
1
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vivo dynamic optical coherence tomography of human skin with hardware- and software-based motion correction

Carmen Bao, Rion Morishita, Shingo Sakai, Ibrahim El-Sadek et al.
1 citations
Biomedical Optics Express
Optical Coherence Tomography Applications
article

In vivo dynamic optical coherence tomography of human skin with hardware- and software-based motion correction

Carmen Bao, Rion Morishita, Shingo Sakai, Ibrahim El-Sadek, Yiheng Lim, Hiroyuki Yoshida, Shuichi Makita, Kohei Yamazaki, Pradipta Mukherjee, Keiichi Sugata, Shinya Kasamatsu, Guo Yu
article en
1 citations

Abstract

In vivo application of dynamic optical coherence tomography (DOCT) is hindered by bulk motion of the sample. We demonstrate DOCT imaging of in vivo human skin by adopting a sample-fixation attachment to suppress bulk motion and a subsequent software motion correction to further reduce the effect of sample motion. The performance of the motion-correction method was assessed by DOCT image observation, statistical analysis of the mean DOCT values, and subjective image grading. Both the mean DOCT value analysis and subjective grading showed statistically significant improvement of the DOCT image quality. In addition, a previously unobserved high DOCT layer was identified though image observation, which may represent the stratum basale with high keratinocyte proliferation.

Biomedical Optics ExpressVol. 17(3)
Kao Corporation (Germany) (DE), CTS Corporation (Czechia) (CZ)
Openalex Percentile: Top 100%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

<i>In vivo</i> dynamic optical coherence tomography of human skin with hardware- and software-based motion correction — Carmen Bao, Rion Morishita, et al. · Biomedical Optics Express (2026) | TGRS Research Map | TGRS