DESIGN OF VERTICAL THOMSON SCATTERING DIAGNOSTICS FOR THE T-15MD TOKAMAK

For measuring the parameters of the plasma electron component in the T-15MD tokamak, the complex of Thomson scattering diagnostics is being designed, which will make it possible to study different regions of the plasma. In this work, we discuss the design of the Thomson scattering system with vertical probing for T-15MD, which provides for information on the plasma parameters along the vertical diameter of the vacuum vessel. Plasma probing is performed using the Nd:YAG laser with multipass system for inject laser beam into the tokamak. The laser operates at the second harmonic λ = 532 nm. Scattered radiation is collected by one wide-angle lens. Light is transmitted to the registration system by the fiber-optic collector consisting of 159 fiber-optic assemblies with the size 2 × 1 mm. The registration system consists of three units; each unit includes relay optical system and polychromator with detector. The spectrum of scattered radiation is recorded using image intensifier with CMOS camera. For achieving high light transmittance of the diagnostics optical system, the parameters and design of each optical unit were calculated in detail: the collecting lens, the relay optical system, and the polychromator. As compared to the T-10 Thomson scattering diagnostics, the system transmittance was considerably improved due to selecting rigorously the optical materials, as well as applying new design of the relay optical system, consisting mainly of mirrors. Using synthetic diagnostics, the accuracy of measuring the electron temperature and density was estimated. The plasma spectra from the region of T-15MD limiter are used as the plasma background. The Thomson scattering diagnostics system with vertical probing will make it possible to measure the electron temperature of plasma of the T-15MD tokamak with an error of less than 10% in the range from 80 eV to 6 keV at an electron density of more than 6 × 1018 m−3 in the central plasma region. At the plasma edge, the error will be less than 10% for the

Authors

Publication Details

Journal
Физика плазмы / Plasma Physics Reports
Published
2025-01-01
DOI
https://doi.org/10.7868/s3034637125010019
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DESIGN OF VERTICAL THOMSON SCATTERING DIAGNOSTICS FOR THE T-15MD TOKAMAK

Д. С. Панфилов
Физика плазмы / Plasma Physics Reports
Magnetic confinement fusion research
article

DESIGN OF VERTICAL THOMSON SCATTERING DIAGNOSTICS FOR THE T-15MD TOKAMAK

Д. С. Панфилов
article en

Abstract

For measuring the parameters of the plasma electron component in the T-15MD tokamak, the complex of Thomson scattering diagnostics is being designed, which will make it possible to study different regions of the plasma. In this work, we discuss the design of the Thomson scattering system with vertical probing for T-15MD, which provides for information on the plasma parameters along the vertical diameter of the vacuum vessel. Plasma probing is performed using the Nd:YAG laser with multipass system for inject laser beam into the tokamak. The laser operates at the second harmonic λ = 532 nm. Scattered radiation is collected by one wide-angle lens. Light is transmitted to the registration system by the fiber-optic collector consisting of 159 fiber-optic assemblies with the size 2 × 1 mm. The registration system consists of three units; each unit includes relay optical system and polychromator with detector. The spectrum of scattered radiation is recorded using image intensifier with CMOS camera. For achieving high light transmittance of the diagnostics optical system, the parameters and design of each optical unit were calculated in detail: the collecting lens, the relay optical system, and the polychromator. As compared to the T-10 Thomson scattering diagnostics, the system transmittance was considerably improved due to selecting rigorously the optical materials, as well as applying new design of the relay optical system, consisting mainly of mirrors. Using synthetic diagnostics, the accuracy of measuring the electron temperature and density was estimated. The plasma spectra from the region of T-15MD limiter are used as the plasma background. The Thomson scattering diagnostics system with vertical probing will make it possible to measure the electron temperature of plasma of the T-15MD tokamak with an error of less than 10% in the range from 80 eV to 6 keV at an electron density of more than 6 × 1018 m−3 in the central plasma region. At the plasma edge, the error will be less than 10% for the

Физика плазмы / Plasma Physics ReportsVol. 51(1)
Openalex Percentile: Top 87%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

DESIGN OF VERTICAL THOMSON SCATTERING DIAGNOSTICS FOR THE T-15MD TOKAMAK — Д. С. Панфилов · Физика плазмы / Plasma Physics Reports (2025) | TGRS Research Map | TGRS