Demand Response Based Optimally Modified Fractional Cascade Controller in Hybrid AGC Incorporating EV.

In this article, a well-known Demand Response (DR) approach is presented as a novel frequency regulation control mechanism in a deregulated environment. Examining how Automatic Generation Control (AGC) in a hybrid restructured power system accounts for the intermittent nature of EVs and Renewable Energy Sources (RESs) is the objective of the research. The Demand Response (DR) is incorporating with hybrid AGC. In addition to two different energy sources thermal and bio plant in each control area, the power system under investigation includes verified real-time nonlinearities, such as boiler dynamics, Governor Dead Band (GDB), and Generation Rate Constraint (GRC). For both scheduled and unscheduled electricity under different contracts, such as poolco, bilateral transaction and contract violation transactions. Three controllers PID, TIDN, and 2DOF(FOPI)-TDN (proposed) are incorporated across a variety of power transform model. The proposed controller is cascade combination of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$2 \text{DOF}(\text{FOPI})$</tex> and TDN controllers. Furthermore, RESs like wind and solar power plants are proposed as case studies with random load. The effectiveness of proposed controller is compared with existing controller. To optimize the various gain parameters of the proposed controller, a modified version of the Opposition based Arithmetic Optimization Techniques (OAOT) has been proposed. Different results and case study analysis has been conducted under poolco-based transactions to verify the suggested controller's resilience and adaptability. The effect of EV is analysis with AGC.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/ne-iecce64154.2025.11183305
Primary Topic
Advanced Control Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Demand Response Based Optimally Modified Fractional Cascade Controller in Hybrid AGC Incorporating EV.

Ashiwani Kumar, Prabhat Kumar Vidyarthi, Ravi Shankar
Advanced Control Systems Optimization
article

Demand Response Based Optimally Modified Fractional Cascade Controller in Hybrid AGC Incorporating EV.

Ashiwani Kumar, Prabhat Kumar Vidyarthi, Ravi Shankar
article en

Abstract

In this article, a well-known Demand Response (DR) approach is presented as a novel frequency regulation control mechanism in a deregulated environment. Examining how Automatic Generation Control (AGC) in a hybrid restructured power system accounts for the intermittent nature of EVs and Renewable Energy Sources (RESs) is the objective of the research. The Demand Response (DR) is incorporating with hybrid AGC. In addition to two different energy sources thermal and bio plant in each control area, the power system under investigation includes verified real-time nonlinearities, such as boiler dynamics, Governor Dead Band (GDB), and Generation Rate Constraint (GRC). For both scheduled and unscheduled electricity under different contracts, such as poolco, bilateral transaction and contract violation transactions. Three controllers PID, TIDN, and 2DOF(FOPI)-TDN (proposed) are incorporated across a variety of power transform model. The proposed controller is cascade combination of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$2 \text{DOF}(\text{FOPI})$</tex> and TDN controllers. Furthermore, RESs like wind and solar power plants are proposed as case studies with random load. The effectiveness of proposed controller is compared with existing controller. To optimize the various gain parameters of the proposed controller, a modified version of the Opposition based Arithmetic Optimization Techniques (OAOT) has been proposed. Different results and case study analysis has been conducted under poolco-based transactions to verify the suggested controller's resilience and adaptability. The effect of EV is analysis with AGC.

National Institute of Technology Patna (IN)
Openalex Percentile: Top 64%
Advanced Control Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Demand Response Based Optimally Modified Fractional Cascade Controller in Hybrid AGC Incorporating EV. — Ashiwani Kumar, Prabhat Kumar Vidyarthi, et al. · (2025) | TGRS Research Map | TGRS