Robust Strategy for Agc and Avr in Isolated Hydropower Plants

Performance of automatic generation control (AGC) and automatic voltage regulation (AVR) of a hydropower system is susceptible to load perturbations and cyberattacks, such as false data injection (FDI), which can significantly disrupt both frequency and voltage control. However, very few works in literature consider both AGC and AVR. Hence, this paper focuses on a robust AGC and AVR strategy deploying appropriate controllers. These controllers are of simple PID (for AGC) and PI (for AVR) type, analytically designed using the moments matching method. The single-tuning parameters of the aforementioned controllers are designed using the integral of time-weighted absolute error, computed from AGC and AVR loops. This simple and robust method enhances system resilience and ensures improved stability under cyberthreat conditions compared to some existing analytical controller design methods.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/ne-iecce64154.2025.11183090
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust Strategy for Agc and Avr in Isolated Hydropower Plants

Gagan Deep Meena, Gautam Singh, G. Lloyds Raja, Deepak Kumar et al.
Cavitation Phenomena in Pumps
article

Robust Strategy for Agc and Avr in Isolated Hydropower Plants

Gagan Deep Meena, Gautam Singh, G. Lloyds Raja, Deepak Kumar, Sudipta Chakraborty, Akash Kumar Deep
article en

Abstract

Performance of automatic generation control (AGC) and automatic voltage regulation (AVR) of a hydropower system is susceptible to load perturbations and cyberattacks, such as false data injection (FDI), which can significantly disrupt both frequency and voltage control. However, very few works in literature consider both AGC and AVR. Hence, this paper focuses on a robust AGC and AVR strategy deploying appropriate controllers. These controllers are of simple PID (for AGC) and PI (for AVR) type, analytically designed using the moments matching method. The single-tuning parameters of the aforementioned controllers are designed using the integral of time-weighted absolute error, computed from AGC and AVR loops. This simple and robust method enhances system resilience and ensures improved stability under cyberthreat conditions compared to some existing analytical controller design methods.

National Institute of Technology Patna (IN), National Institute Of Technology Silchar (IN), United Arab Emirates University (AE)
Openalex Percentile: Top 67%
Cavitation Phenomena in Pumps
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.