Operation Risk Based Optimal μPMU Placement in Distribution Network Considering Radial Buses

This paper proposes an operation risk-based optimal Micro-PMU (μPMU) deployment strategy in distribution networks excluding μPMUs at radial buses. Radial buses are with single connectivity. Therefore, a radial bus μPMU decreases measurement redundancy, popularly known as system observability redundancy index (SORI). A reduced SORI has adverse effects during contingency such as μPMU outage condition. On the other hand, the operation risk of a node is pivotal for determining μPMU locations. Existing literature shows that μPMUs must be placed at radial buses having lower operation risk to avoid loss of observability (LoB). This consideration is certainly true for unreliable node outage consideration. However, this is not true for μPMU outage consideration. During μPMU outage conditions, each bus except radial buses should be doubly observable due to technoeconomic reasons. Therefore, excluding radial buses from direct metering enhances SORI as well as meter procurement costs. The proposed algorithm simulated on IEEE 33 bus system explicitly shows its efficacy in terms of Total System Operation Risk, LoB, and SORI.

Authors

Institutions

Publication Details

Published
2025-07-04
DOI
https://doi.org/10.1109/ne-iecce64154.2025.11183179
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operation Risk Based Optimal μPMU Placement in Distribution Network Considering Radial Buses

Biman Kumar Saha Roy, Manas Mukherjee
Power Systems and Technologies
article

Operation Risk Based Optimal μPMU Placement in Distribution Network Considering Radial Buses

Biman Kumar Saha Roy, Manas Mukherjee
article en

Abstract

This paper proposes an operation risk-based optimal Micro-PMU (μPMU) deployment strategy in distribution networks excluding μPMUs at radial buses. Radial buses are with single connectivity. Therefore, a radial bus μPMU decreases measurement redundancy, popularly known as system observability redundancy index (SORI). A reduced SORI has adverse effects during contingency such as μPMU outage condition. On the other hand, the operation risk of a node is pivotal for determining μPMU locations. Existing literature shows that μPMUs must be placed at radial buses having lower operation risk to avoid loss of observability (LoB). This consideration is certainly true for unreliable node outage consideration. However, this is not true for μPMU outage consideration. During μPMU outage conditions, each bus except radial buses should be doubly observable due to technoeconomic reasons. Therefore, excluding radial buses from direct metering enhances SORI as well as meter procurement costs. The proposed algorithm simulated on IEEE 33 bus system explicitly shows its efficacy in terms of Total System Operation Risk, LoB, and SORI.

University of Engineering & Management (IN), National Institute of Technology Durgapur (IN)
Openalex Percentile: Top 72%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Operation Risk Based Optimal μPMU Placement in Distribution Network Considering Radial Buses — Biman Kumar Saha Roy, Manas Mukherjee · (2025) | TGRS Research Map | TGRS