Correlation Analysis of Wind Speed and Grid Interruption-induced Outages and Energy Losses in North Central States, Nigeria

Despite the widespread use of power in Nigeria, the electricity supply suffer power deficit, poor quality and sporadic supply especially in the North Central States. Most overhead transmission lines are exposed to natural phenomena especially strong wind which can cause vibration in the conductors and cause the conductors to become closer to or separate away from the body of the tower leading to power outage. This study examined the effect of wind speed on grid interruption and outages in North Central States of Nigeria using correlation analysis of three years NASA wind speed data obtained from NASA/POWER CERES/MERRA2 (2020-2022) and utility outage records. Result shows that, wind speed is observed to be stronger in January, February, August and December throughout the three years period especially January and December. For wind speed at 10m, the total load losses were 121.15MW, 789.5MW and 58.5MW which amounted to energy losses 431.7MWH, 2203.8MWH and 216.8MWH in 2020, 2021 and 2022 respectively. Similarly, for wind speed at 50m, the total load losses were 169.68MW, 1689.17MW and 80.2MW with corresponding energy losses 604.38MWH, 4715.66MWH and 325.21MWH respectively. Out of the total energy losses, wind speed at 10m contributed 46.4%, 25.9% and 29.4%, while wind speed at 50m contributed 64.9%, 54.9% and 50.0% in 2020, 2021 and 2022 respectively. Also, wind speed at 50m range has highest speed across the 3 years. This implies that wind at 50m is a more significant factor for outages than wind at 10m, regression coefficient R2 = 0.121 against 0.050 and unstandardized beta coefficient β = 0.348 against –0.223 at 95% CI, suggesting issues with taller structures or vegetation contact. The findings of this study are relevant for power grid operators, policymakers, and infrastructure planners in Nigeria, highlight the importance of improving power infrastructure, regular scheduled maintenance most especially at the beginning of the year when wind speed is high in North Central States of Nigeria.

Authors

Institutions

Publication Details

Journal
Journal of Energy Research and Reviews
Published
2025-10-10
DOI
https://doi.org/10.9734/jenrr/2025/v17i10465
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation Analysis of Wind Speed and Grid Interruption-induced Outages and Energy Losses in North Central States, Nigeria

Samson Dauda Yusuf, Ibrahim Umar, Daniel Ime Akpan
Journal of Energy Research and Reviews
Thermal Analysis in Power Transmission
article

Correlation Analysis of Wind Speed and Grid Interruption-induced Outages and Energy Losses in North Central States, Nigeria

Samson Dauda Yusuf, Ibrahim Umar, Daniel Ime Akpan
article en

Abstract

Despite the widespread use of power in Nigeria, the electricity supply suffer power deficit, poor quality and sporadic supply especially in the North Central States. Most overhead transmission lines are exposed to natural phenomena especially strong wind which can cause vibration in the conductors and cause the conductors to become closer to or separate away from the body of the tower leading to power outage. This study examined the effect of wind speed on grid interruption and outages in North Central States of Nigeria using correlation analysis of three years NASA wind speed data obtained from NASA/POWER CERES/MERRA2 (2020-2022) and utility outage records. Result shows that, wind speed is observed to be stronger in January, February, August and December throughout the three years period especially January and December. For wind speed at 10m, the total load losses were 121.15MW, 789.5MW and 58.5MW which amounted to energy losses 431.7MWH, 2203.8MWH and 216.8MWH in 2020, 2021 and 2022 respectively. Similarly, for wind speed at 50m, the total load losses were 169.68MW, 1689.17MW and 80.2MW with corresponding energy losses 604.38MWH, 4715.66MWH and 325.21MWH respectively. Out of the total energy losses, wind speed at 10m contributed 46.4%, 25.9% and 29.4%, while wind speed at 50m contributed 64.9%, 54.9% and 50.0% in 2020, 2021 and 2022 respectively. Also, wind speed at 50m range has highest speed across the 3 years. This implies that wind at 50m is a more significant factor for outages than wind at 10m, regression coefficient R2 = 0.121 against 0.050 and unstandardized beta coefficient β = 0.348 against –0.223 at 95% CI, suggesting issues with taller structures or vegetation contact. The findings of this study are relevant for power grid operators, policymakers, and infrastructure planners in Nigeria, highlight the importance of improving power infrastructure, regular scheduled maintenance most especially at the beginning of the year when wind speed is high in North Central States of Nigeria.

Journal of Energy Research and ReviewsVol. 17(10)
Nasarawa State University (NG)
Openalex Percentile: Top 64%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.