A comparative analysis of accuracy and sensitivity in semen testing: <scp>ABAcard p30™</scp> , <scp>RSID Semen™</scp> , and Seratec <scp>PSA™</scp>

Confirmatory semen tests are used to determine the possible presence of semen in an evidence sample. Current test kits target proteins like PSA and semenogelin, but these markers can yield false positive results when identifying potential semen evidence. This study evaluated the sensitivity and specificity of three rapid immunochromatographic semen detection kits: RSID™ Semen, Seratec™ PSA, and ABAcard™ p30. These kits are marketed as confirmatory tests for semen. Test samples included serial semen dilutions, bodily fluids, and materials previously shown to cause false positives. All tests were performed according to manufacturers' protocols. Combined test results indicated a 9.4% false positive rate. False positives occurred across all kits with absorbent hygiene products (e.g., tampons, menstrual pads, and diapers). RSID™ Semen failed to detect semen in a 1:10,000 dilution and when mixed with dirt, indicating a 3% false negative rate and a false positive rate of 9%. ABAcard™ p30 produced false positives with female urine. While Seratec™ PSA demonstrated the highest sensitivity with only a 1% false negative rate, its false positive rate (12%) was the highest observed. ABAcard™ p30 exhibited superior performance with the lowest false positive rate (6%) and a false negative rate of 2%. While most forensic labs have moved away from using these kits as confirmatory tests, it is vital to emphasize why reporting their results as definitive semen evidence is problematic. These tests cannot confirm semen presence and should not be used alone as confirmatory evidence in forensic reports.

Authors

Institutions

Publication Details

Journal
Journal of Forensic Sciences
Published
2025-10-09
DOI
https://doi.org/10.1111/1556-4029.70194
Citations
1
Primary Topic
Forensic and Genetic Research
Type
article
Field-Weighted Citation Impact
1.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparative analysis of accuracy and sensitivity in semen testing: ABAcard p30™ , RSID Semen™ , and Seratec PSA™

Heather Rogers, R. Williams
1 citations
Journal of Forensic Sciences
Forensic and Genetic Research
1.82
article

A comparative analysis of accuracy and sensitivity in semen testing: ABAcard p30™ , RSID Semen™ , and Seratec PSA™

Heather Rogers, R. Williams
article en
1 citations

Abstract

Confirmatory semen tests are used to determine the possible presence of semen in an evidence sample. Current test kits target proteins like PSA and semenogelin, but these markers can yield false positive results when identifying potential semen evidence. This study evaluated the sensitivity and specificity of three rapid immunochromatographic semen detection kits: RSID™ Semen, Seratec™ PSA, and ABAcard™ p30. These kits are marketed as confirmatory tests for semen. Test samples included serial semen dilutions, bodily fluids, and materials previously shown to cause false positives. All tests were performed according to manufacturers' protocols. Combined test results indicated a 9.4% false positive rate. False positives occurred across all kits with absorbent hygiene products (e.g., tampons, menstrual pads, and diapers). RSID™ Semen failed to detect semen in a 1:10,000 dilution and when mixed with dirt, indicating a 3% false negative rate and a false positive rate of 9%. ABAcard™ p30 produced false positives with female urine. While Seratec™ PSA demonstrated the highest sensitivity with only a 1% false negative rate, its false positive rate (12%) was the highest observed. ABAcard™ p30 exhibited superior performance with the lowest false positive rate (6%) and a false negative rate of 2%. While most forensic labs have moved away from using these kits as confirmatory tests, it is vital to emphasize why reporting their results as definitive semen evidence is problematic. These tests cannot confirm semen presence and should not be used alone as confirmatory evidence in forensic reports.

Journal of Forensic SciencesVol. 71(1)
University of Central Oklahoma (US)
Openalex Percentile: Top 12%
Forensic and Genetic Research
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.