Proof-of-concept testing of passive sampling of sewer gas for VOC Vapors using the waterloo membrane sampler™

• Passive time-weighted average samples minimize uncertainty due to temporal variability in sewer headspace • WMS™ performs well for monitoring concentrations of volatile vapors in sewer headspace • WMS™ membrane is protected from condensation in sewer headspace Sewer gas ingress to houses has recently been identified as a pathway of potential human health concern for volatile organic compounds (VOCs) such as chlorinated solvents and petroleum hydrocarbons at or near regulated contaminated sites. This is a relatively new field of assessment and raises questions regarding monitoring methods. This article provides data to compare a passive sampling alternative to active grab samples for sewer headspace VOC vapor monitoring. Passive sampling has several potential advantages, including fewer sampling events needed compared to active grab sampling for confident assessment of time-weighted average (TWA) concentrations, reducing the carbon footprint. The Waterloo Membrane Sampler™ (WMS™) has a hydrophobic membrane to limit interference attributable to water vapor and small size to enable deployment through holes in maintenance covers without lifting the cover. This paper describes a proof-of-concept field trial conducted in three events. The WMS™ results show good precision and reproducibility and reasonable accuracy, considering temporal variability throughout the sampling period was not explicitly determined. Furthermore, collection of longer-duration TWA samples has less susceptibility to bias from temporal variability compared to active grab samples. The WMS™ data showed much lower reporting limits than the TO-15 full scan analysis and quantified several compounds that were not detected by the TO-15 full scan analysis. The WMS™ also showed good durability over extended sample durations in a humid environment, with no special considerations for security, ease of use, shipping, storage and handling, and comparable cost to the active sampling method.

Authors

Institutions

Publication Details

Journal
Green Analytical Chemistry
Published
2025-10-10
DOI
https://doi.org/10.1016/j.greeac.2025.100303
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proof-of-concept testing of passive sampling of sewer gas for VOC Vapors using the waterloo membrane sampler™

Brent G. Pautler, Todd McAlary, Heidi Hayes, A. Inglis
Green Analytical Chemistry
Analytical Chemistry and Sensors
article

Proof-of-concept testing of passive sampling of sewer gas for VOC Vapors using the waterloo membrane sampler™

Brent G. Pautler, Todd McAlary, Heidi Hayes, A. Inglis
article en

Abstract

• Passive time-weighted average samples minimize uncertainty due to temporal variability in sewer headspace • WMS™ performs well for monitoring concentrations of volatile vapors in sewer headspace • WMS™ membrane is protected from condensation in sewer headspace Sewer gas ingress to houses has recently been identified as a pathway of potential human health concern for volatile organic compounds (VOCs) such as chlorinated solvents and petroleum hydrocarbons at or near regulated contaminated sites. This is a relatively new field of assessment and raises questions regarding monitoring methods. This article provides data to compare a passive sampling alternative to active grab samples for sewer headspace VOC vapor monitoring. Passive sampling has several potential advantages, including fewer sampling events needed compared to active grab sampling for confident assessment of time-weighted average (TWA) concentrations, reducing the carbon footprint. The Waterloo Membrane Sampler™ (WMS™) has a hydrophobic membrane to limit interference attributable to water vapor and small size to enable deployment through holes in maintenance covers without lifting the cover. This paper describes a proof-of-concept field trial conducted in three events. The WMS™ results show good precision and reproducibility and reasonable accuracy, considering temporal variability throughout the sampling period was not explicitly determined. Furthermore, collection of longer-duration TWA samples has less susceptibility to bias from temporal variability compared to active grab samples. The WMS™ data showed much lower reporting limits than the TO-15 full scan analysis and quantified several compounds that were not detected by the TO-15 full scan analysis. The WMS™ also showed good durability over extended sample durations in a humid environment, with no special considerations for security, ease of use, shipping, storage and handling, and comparable cost to the active sampling method.

Green Analytical ChemistryVol. 15
International Consultants (Egypt) (EG), Geosyntec Consultants (United States) (US), Eurofins (France) (FR), University of Guelph (CA)
Openalex Percentile: Top 62%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.