Evaluation of Size-Specific Dose Estimates in Pediatric Abdominal CT

In pediatric abdominal CT examinations, the conventional CT dose index (CTDIvol) has limitations as it does not account for the patient’s body size. To address this issue, the American Association of Physicists in Medicine (AAPM) introduced the concept of size-specific dose estimate (SSDE), which considers individual patient body size. This study retrospectively analyzed the SSDE of pediatric patients aged 1 to 5 years and compared it with the CTDIvol provided by the CT equipment. The results showed that SSDE values were 2.16 to 2.34 times those of CTDIvol, indicating the potential underestimation of actual radiation exposure in pediatric patients. Additionally, among the four SSDE conversion methods proposed by the AAPM, the method using only the anteroposterior diameter was found to be statistically insignificant.(p>0.05) In contrast, the method incorporating both anteroposterior (AP) and lateral diameters was recommended. This is likely because the lateral diameter in pediatric patients increases linearly with age, whereas the AP diameter does not show a linear trend. Currently, there is an international movement to establish SSDE as the new standard for dose estimation, as it more accurately reflects actual radiation exposure. Therefore, SSDE should be actively incorporated alongside CTDI in CT examinations for more effective radiation dose management.

Authors

Publication Details

Journal
Korean Society of Computed Tomographic Technology
Published
2025-09-30
DOI
https://doi.org/10.31320/jksct.2025.27.2.93
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Size-Specific Dose Estimates in Pediatric Abdominal CT

Christina H. Son, Yoon-Chul Nam, Sang Hun Kim, Min-Kyeong Kim
Korean Society of Computed Tomographic Technology
Radiation Dose and Imaging
article

Evaluation of Size-Specific Dose Estimates in Pediatric Abdominal CT

Christina H. Son, Yoon-Chul Nam, Sang Hun Kim, Min-Kyeong Kim
article en

Abstract

In pediatric abdominal CT examinations, the conventional CT dose index (CTDIvol) has limitations as it does not account for the patient’s body size. To address this issue, the American Association of Physicists in Medicine (AAPM) introduced the concept of size-specific dose estimate (SSDE), which considers individual patient body size. This study retrospectively analyzed the SSDE of pediatric patients aged 1 to 5 years and compared it with the CTDIvol provided by the CT equipment. The results showed that SSDE values were 2.16 to 2.34 times those of CTDIvol, indicating the potential underestimation of actual radiation exposure in pediatric patients. Additionally, among the four SSDE conversion methods proposed by the AAPM, the method using only the anteroposterior diameter was found to be statistically insignificant.(p>0.05) In contrast, the method incorporating both anteroposterior (AP) and lateral diameters was recommended. This is likely because the lateral diameter in pediatric patients increases linearly with age, whereas the AP diameter does not show a linear trend. Currently, there is an international movement to establish SSDE as the new standard for dose estimation, as it more accurately reflects actual radiation exposure. Therefore, SSDE should be actively incorporated alongside CTDI in CT examinations for more effective radiation dose management.

Korean Society of Computed Tomographic TechnologyVol. 27(2)
Openalex Percentile: Top 58%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Size-Specific Dose Estimates in Pediatric Abdominal CT — Christina H. Son, Yoon-Chul Nam, et al. · Korean Society of Computed Tomographic Technology (2025) | TGRS Research Map | TGRS