An Immunocompatible Conductive Polymer for Long-Term Bioelectronic Implants

Tissue-electronic interfaces are vital for neural implants, health monitoring devices, and augmented reality applications; however, the host immune reaction against the electrodes profoundly impacts their durability, precision, and overall fidelity. Building a highly immunocompatible yet conductive interface for implantable electrodes remains a significant challenge. Here, by screening PEDOT derivatives functionalized with diverse immunoregulatory moieties, we identified PEDOT-TMO as a candidate combining superior immunocompatibility with robust conductivity for long-term bioelectronic implants. PEDOT-TMO/PSS coatings exhibit substantially mitigated acute inflammation and chronic fibrotic response following subcutaneous implantation in mice compared to conventional PEDOT/PSS, while preserving its original electrochemical properties. During extended in vivo brain implantation trials in freely moving rat models, we observed that the immunocompatible conductive polymer-coated silicon electrode can reliably record electrophysiological signals for at least 8 weeks, demonstrating significantly better performance compared to PEDOT/PSS-coated and bare electrodes. Notably, the PEDOT-TMO/PSS interface substantially reduced the expression of S100A9 in surrounding brain tissue. Pharmacological inhibition of S100A9 similarly attenuated tissue responses to brain implants, suggesting a target for neuroinflammation inhibition. The new type of immunocompatible conductive polymer reported here holds promise in enhancing and extending the long-term function in a range of bioelectronic devices by attenuating local immune responses to functional bioelectrodes.

Authors

Institutions

Publication Details

Journal
Journal of the American Chemical Society
Published
2025-10-10
DOI
https://doi.org/10.1021/jacs.5c07902
Citations
4
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
3.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Immunocompatible Conductive Polymer for Long-Term Bioelectronic Implants

Youxiang Wang, Shaomin Zhang, Zihao Zhu, Zuolong Liu et al.
4 citations
Journal of the American Chemical Society
Neuroscience and Neural Engineering
3.64
article

An Immunocompatible Conductive Polymer for Long-Term Bioelectronic Implants

Youxiang Wang, Shaomin Zhang, Zihao Zhu, Zuolong Liu, Peng Zhang, Xianchi Zhou, Yan Yu, Fan Zhang, Jian Ji, Kexin Chen, Wenzhong Cao, Wenbin Dai, Fan Jia
article en
4 citations

Abstract

Tissue-electronic interfaces are vital for neural implants, health monitoring devices, and augmented reality applications; however, the host immune reaction against the electrodes profoundly impacts their durability, precision, and overall fidelity. Building a highly immunocompatible yet conductive interface for implantable electrodes remains a significant challenge. Here, by screening PEDOT derivatives functionalized with diverse immunoregulatory moieties, we identified PEDOT-TMO as a candidate combining superior immunocompatibility with robust conductivity for long-term bioelectronic implants. PEDOT-TMO/PSS coatings exhibit substantially mitigated acute inflammation and chronic fibrotic response following subcutaneous implantation in mice compared to conventional PEDOT/PSS, while preserving its original electrochemical properties. During extended in vivo brain implantation trials in freely moving rat models, we observed that the immunocompatible conductive polymer-coated silicon electrode can reliably record electrophysiological signals for at least 8 weeks, demonstrating significantly better performance compared to PEDOT/PSS-coated and bare electrodes. Notably, the PEDOT-TMO/PSS interface substantially reduced the expression of S100A9 in surrounding brain tissue. Pharmacological inhibition of S100A9 similarly attenuated tissue responses to brain implants, suggesting a target for neuroinflammation inhibition. The new type of immunocompatible conductive polymer reported here holds promise in enhancing and extending the long-term function in a range of bioelectronic devices by attenuating local immune responses to functional bioelectrodes.

Journal of the American Chemical SocietyVol. 147(42)
Ministry of Education (NZ), Sir Run Run Shaw Hospital (CN), Sivas State Hospital (TR), Ministry of Education (IR), Second Affiliated Hospital of Zhejiang University (CN), Zhejiang University (CN)
Openalex Percentile: Top 6%
Neuroscience and Neural Engineering
3.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.