Conducted Emission Mitigation for Solid-State Transformer using Modulation and Multiple Configuration Techniques

Solid-state transformers have several advantages over conventional 50 Hz transformers. However, the high switching speed of power electronic devices generates electromagnetic interference (EMI) that can cause malfunction. Conducted emission mitigation techniques for solid-state transformers using appropriate modulations and configurations in the QSPICE simulator are analysed in time and frequency domains. Common-mode (CM) emission and reactive power can be improved using proper modulation and configuration techniques for single and multiple solid-state transformers. The single-phase shift modulation has the lowest CM emission and the highest reactive power. In contrast, the triple-phase shift modulation demonstrates the highest CM emission and the lowest reactive power among the various modulation strategies. The CM emission of single and multiple solidstate transformers with dV/dt cancellation capability is below the IEC 62041-2020 standard limits.

Authors

Institutions

Publication Details

Journal
SPIRE - Sciences Po Institutional REpository
Published
2025-05-26
DOI
https://doi.org/10.34746/epe2025-0068
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conducted Emission Mitigation for Solid-State Transformer using Modulation and Multiple Configuration Techniques

Steve Greedy, Niek Moonen, Alan J. Watson, Hafte Hayelom Adhena
SPIRE - Sciences Po Institutional REpository
Power Transformer Diagnostics and Insulation
article

Conducted Emission Mitigation for Solid-State Transformer using Modulation and Multiple Configuration Techniques

Steve Greedy, Niek Moonen, Alan J. Watson, Hafte Hayelom Adhena
article en

Abstract

Solid-state transformers have several advantages over conventional 50 Hz transformers. However, the high switching speed of power electronic devices generates electromagnetic interference (EMI) that can cause malfunction. Conducted emission mitigation techniques for solid-state transformers using appropriate modulations and configurations in the QSPICE simulator are analysed in time and frequency domains. Common-mode (CM) emission and reactive power can be improved using proper modulation and configuration techniques for single and multiple solid-state transformers. The single-phase shift modulation has the lowest CM emission and the highest reactive power. In contrast, the triple-phase shift modulation demonstrates the highest CM emission and the lowest reactive power among the various modulation strategies. The CM emission of single and multiple solidstate transformers with dV/dt cancellation capability is below the IEC 62041-2020 standard limits.

SPIRE - Sciences Po Institutional REpository
University of Nottingham (GB), Printed Electronics (United Kingdom) (GB), University of Twente (NL)
Openalex Percentile: Top 72%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.