Carbon Black and PEDOT:PSS in a Synergistic Solid Contact for Reliable Printed Potentiometric Sensors
Printed potentiometric sensors require reliable solid contacts to provide stable and reproducible ion-selective electrodes. However, hampering fabrications and unfavorable maintenance often hinder their breakthrough on a commercial scale. Herein, we develop a solid-contact calcium-selective screen-printed electrode harnessing straightforward manufacturing based on the combination of carbon black (CB) and poly(3,4-ethylene dioxythiophene) doped with poly(sodium 4-styrenesulfonate) (PEDOT:PSS) as an ion-to-electron transducer. Drop-casting was used to simply deposit the CB layer, while PEDOT:PSS was rapidly electropolymerized (71 s) onto the working electrode to deliver affordable manufacturing of the printed electrode while ensuring valid potentiometric performance. Subsequently, the ion-selective membrane (ISM) and the polyvinyl butyral (PVB)-based reference membrane were, respectively, drop-cast onto the working electrode and reference electrode (RE). Upon the optimization of solid-contact layers, the solid-contact Ca<sup>2+</sup>-ISEs were investigated by evaluating their potentiometric performance versus a conventional RE. CB/PEDOT:PSS-modified screen-printed electrodes demonstrated a low-frequency capacitance of 55 μF, and an outstanding standard potential interelectrode reproducibility (±1 mV). The combination of both types of ion-to-electron transducers provided calcium detection in the linear range 10<sup>-1</sup>-10<sup>-7</sup> M with a Nernstian sensitivity (28.3 ± 0.3 mV/decade), ensured over 28 days under dry storage. Furthermore, the absence of the water layer effect was also demonstrated. Lastly, the fully printed platform was assembled to achieve a miniaturized and easily field-deployable potentiometric device, consisting of CB/PEDOT:PSS/ISM configuration and PVB-based reference membrane on the working electrode and the RE, respectively. The resulted all-solid-state sensor revealed a Nernstian sensitivity with a 29.0 ± 0.5 mV/decade slope and a stable signal up to 72 h (drift = -0.2 mV/h). Analysis carried out using commercially available bottled water also demonstrated the sensor successful performance in the determination of calcium ion in real samples.
Authors
- Federico Olivieri (ORCID: https://orcid.org/0000-0002-1424-1257)
- Vincenzo Mazzaracchio (ORCID: https://orcid.org/0000-0002-7851-4883)
- Johan Bobacka (ORCID: https://orcid.org/0000-0003-2346-9947)
- Gennaro Gentile (ORCID: https://orcid.org/0000-0002-1280-8926)
- Fabiana Arduini (ORCID: https://orcid.org/0000-0001-8990-6922)
- Luca De Fiore (ORCID: https://orcid.org/0000-0003-0067-063X)
- Zekra Mousavi (ORCID: https://orcid.org/0000-0002-5020-7478)
- Christian Gosti
Institutions
- University of Rome Tor Vergata (IT)
- Åbo Akademi University (FI)
- Institute of Polymers, Composites and Biomaterials (IT)
Publication Details
- Journal
- ACS Sensors
- Published
- 2025-10-09
- DOI
- https://doi.org/10.1021/acssensors.5c02226
- Citations
- 3
- Primary Topic
- Analytical Chemistry and Sensors
- Type
- article
- Field-Weighted Citation Impact
- 2.21